Nokia Customer Care
Disconnect the power supply from the phone and use an ohmmeter to check that inductor is
conducting DC.
3.1.1.1.2 RFBUS signals ok?
GSM receiver has to be active before RFBUS signals can be measured. Procedure is explained in
section "GSM RX chain activation for manual measurements". Also WCDMA/GSM transmitter and
WCDMA receiver activation can be used for the measurement but then RFBUS -signals don't
necessarily look like in figures mentioned below.
Measurements can be performed with an oscilloscope and a probe. Check all five RF BUS signals:
RFBUSDAT: Connect the probe to J7504. Typical RFBUSDAT -signal is shown in section 6.5.9.3
-
"RFBUSDAT (GSM
RFBUSCLK: Connect the probe to J7505. Typical RFBUSCLK -signal is shown in sections 6.5.9.1
-
"RFUSCLK (GSM
RFBUSENA: Connect the probe to J7506. Typical RFBUSENA -signal is shown in section 6.5.9.2
-
"RFBUSCLK and RFBUSENA (GSM
RXRESETX: Connect the probe to J7515. RXRESETX -signal is a constant 2 V DC-signal after GSM or
-
WCDMA transceiver has been activated the first time after phone boot up. The level of this signal
should be about 0 V before transceiver activation.
TXRESETX: Connect the probe to J7517. TXRESETX -signal is a constant 2 V DC-signal after GSM or
-
WCDMA transceiver has been activated the first time after phone boot up. The level of this signal
should be about 0 V before transceiver activation.
3.1.1.1.2.1 RAP3G (or Vinku or Hinku) faulty?
RAP3G (D2800) cannot be replaced.
3.1.1.1.3 Vinku (N7501) regulator voltages VREG1, VREG2 ok?
GSM transmitter has to be active before VREG1 and VREG2 voltages can be measured. Procedure is
explained in section "Transmitter troubleshooting."
Measurements can be done with an oscilloscope and a probe.
VREG1: Connect the probe to C7543
VREG2: Connect the probe to C7548 (or C7547)
VREG1 and VREG2 voltage levels should be 2.65 – 2.86 V. Typical value is 2.7 V.
3.1.1.1.3.1 Vinku (N7501) RB_EXT voltage ok?
GSM transmitter has to be active before Vinku's RB_EXT voltage can be measured. Procedure is
explained in section "Transmitter troubleshooting".