hit counter script

Is Capacitor C7579 In Wcdma Pa (N7503) Bias Line In Place; Are Capacitors In Vinku Reg1 And Reg2 Lines In Place; Are Capacitors In Wcdma Pa Power Supply Lines In Place; Are Tx-Iq Signals Ok - Nokia 6680 RM-36 Service Manual

Mobile terminal
Table of Contents

Advertisement

Appendix A: RF Troubleshooting

6.3.1 Is capacitor C7579 in WCDMA PA (N7503) bias line in place?

Check that the component is in place and solder joints are ok

6.3.2 Are capacitors in Vinku REG1 and REG2 lines in place?

C7554, C7555 and C7547
Check that components are in place and solder joints are ok

6.3.3 Are capacitors in WCDMA PA power supply lines in place?

C7569 and C7583
Check that components are in place and solder joints are ok

6.3.4 Are TX-IQ signals ok?

These current mode signals are not possible to measure, but are tested with self-tests. So if there
is no fail in section 2.3.
or RAP3G (D2800) is faulty. Notice that it is not possible to replace RAP3G ASIC.

6.3.5 Is TX VCO signal level in the T7503 output high enough?

WCDMA transmitter has to be active before TX VCO's output level can be measured. Procedure is
explained in section "Transmitter troubleshooting".
Measurements can be done with a spectrum analyser and an RF probe. Spectrum analyser centre
frequency should be set according the used TX channel (see section "Frequency mappings"). RBW
and VBW = 1 MHz, Span ≤ 200 kHz.
Check the level of the VCO frequency in T7503 outputs. The level should be about -30...-35 dBm in
both output lines. If the signal level is correct in the input (about -25 dBm) but output level is not
as expected then replace T7503. VCO shield has to be removed before measurement. Remember to
solder the shield back after the phone repairing.
6.3.5.1 TX VCO G7502 output level high enough?
WCDMA transmitter has to be active before TX VCO's output frequency and output level can be
measured. Procedure is explained in section "Transmitter troubleshooting".
Measurements can be done with a spectrum analyser and an RF probe. Spectrum analyser centre
frequency should be set according the used TX channel (see section "Frequency mappings"). RBW
and VBW = 1 MHz, Span ≤ 200 kHz.
Connect the RF probe to the T7503 input. VCO shield has to be removed before measurement.
Remember to solder the shield back after the phone repairing.
Check if the frequency of the TX VCO is as expected. If the VCO signal is not found try to use wider
span setting. The output level of the VCO should be about -25 dBm.
6.3.5.1.1 Replace TX VCO G7502
"ST_CDSP_TX_IQ_TEST
Company Confidential
Copyright © 2005 Nokia. All rights reserved
" these signals should be ok. Otherwise Vinku (N7501)
Nokia Customer Care
A-115

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents