hit counter script

Regulators - Nokia 6680 RM-36 Service Manual

Mobile terminal
Table of Contents

Advertisement

RM-36
System Module
Nokia Customer Care
The output signal of the VCTCXO is directly connected to both N7500 and N7501 where it's used as synthesizer
reference. N7500 also contains a balanced buffered output for supplying the clock signal to the digital BB ASIC
and a single ended buffer for Bluetooth.
The frequency of the reference oscillator is locked into the frequency of the base station with the help of an AFC
voltage, which is generated in BB by DSP and converted by dedicated DAC.

Regulators

N7500 and N7501 contain integrated regulators to supply regulated voltages for their internal circuitry and
other RF parts. Rx VCO supply is got via a switch from N7500 VR1 regulator. VCO can be switched on and off by
controlling the switch via RFBus.
Supply voltage for the VCTCXO is provided by a BB mixed mode ASIC. The same supply is used for reference clock
input buffers (in N7500 and N7501), output buffers (from N7500 to BB) and for the digital control blocks of both
RF ASICs. When the VCTCXO regulator is set active, the control blocks of the RF ASICs also wake up. After that the
integrated regulators can be controlled via RFBus.
Other supplies, like 4.7V supply for PLL charge pumps and bias reference (VREFRF01) are also provided by the
BB mixed mode ASIC.
Figure 132 RF supply connections from the BB mixed mode ASIC
Issue 1
Company Confidential
Page 9–53
Copyright ©2005 Nokia. All Rights Reserved.

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents