Installing A Redundant Power Supply Unit; Removing The Power Supply Unit Blank - Dell PowerEdge R330 Owner's Manual

Hide thumbs Also See for PowerEdge R330:
Table of Contents

Advertisement

Installing a redundant power supply unit

Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and
simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support
team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety
instructions that are shipped with your product.
1.
Follow the safety guidelines listed in the Safety instructions section.
2.
Verify that both power supply units (PSUs) are of the same type and have the same maximum output power.
NOTE: The maximum output power (shown in Watt) is listed on the PSU label.
3.
If installed, remove the PSU blank.
Steps
Slide the new PSU into the chassis until the PSU is fully seated and the release latch snaps into place.
Figure 79. Installing a redundant PSU
1.
release latch
3.
PSU handle
Next steps
1.
If you have unlatched the cable management arm, relatch it. For information about the cable management arm, see the rack
documentation of the system.
2.
Connect the power cable to the PSU and plug the cable into a power outlet.
CAUTION: When connecting the power cable, secure the cable with the strap.
NOTE: When installing, hot-swapping, or hot-adding a new PSU in a system with two PSUs, allow several seconds
for the system to recognize the PSU and determine its status. The PSU status indicator turns green to signify that
the PSU is functioning properly.
Related links

Removing the power supply unit blank

Removing the power supply unit blank
Prerequisites
Ensure that you follow the
118
Safety
instructions.
2.
power connector