4
Parts Replacement and Clearning > Fixing > Removing the Pressure Roller
<Processing after replacing the parts>
• Grease Application
Apply approx. 20mg of grease (MOLYKOTE HP-300; CK-8012) to inner circumference and
outer circumference of the Bushing so that all circumferences are covered with white film;
otherwise, abnormal noise can occur (squeaking).
• Clear the counter
COPIER >COUNTER > DRBL-1 > FX-UP-RL
4
Parts Replacement and Clearning > Fixing > Removing the Pressure Roller
Removing the Pressure Roller
<Preparation>
1. Pull out the Fixing Feed Unit. (Refer to "Removing the Fixing Assembly")
2. Remove the Fixing Assembly. (Refer to page 4-176)
3. Remove the Fixing Front Cover. (Refer to "Removing the Fixing Cleaning Web")
4. Remove the Fixing Drive Unit 1. (Refer to "Separating the Fixing Upper Unit from the Fixing
Lower Unit")
5. Secure the Shutter Drive Gear. (Refer to "Separating the Fixing Upper Unit from the Fixing
Lower Unit")
6. Separate the Fixing Upper Unit from the Fixing Lower Unit. (Refer to page 4-182)
<Procedure>
1) Remove the Fixing Inlet Guide.
• 2 Screws
• Wire Saddle
Grease Application
• Edge Saddle
• 1 Connector
F-4-341
Stepped Screw
Screw (Binding)
x2
4-188
F-4-342
4-188