  • Page 1 INSTRUCTION MANUAL Pharmaceutical Refrigerator MPR-1411 MPR-1411R MPR-1411R - 38 - - 38 -...
  • Page 2: Table Of Contents

    CONTENTS INTRODUCTION PRECAUTIONS FOR SAFE OPERATION ENVIRONMENTAL CONDITIONS REFRIGERATOR COMPONENTS Control panel Inside of front cover INSTALLATION SITE INSTALLATION START-UP OF UNIT STOCK OF CONTAINERS CHAMBER TEMPERATURE SETTING ALARM TEMPERATURE SETTING SETTING OF DELAY OF DOOR ALARM SETTING OF ALARM RESUME TIME...
  • Page 3: Introduction

    Contact Sanyo sales representative or agent if any page of the manual is lost or page order is incorrect. Contact Sanyo sales representative or agent if any point in this manual is unclear or if there are any inaccuracies.
  • Page 4: Precautions For Safe Operation

    PRECAUTIONS FOR SAFE OPERATION It is imperative that the user complies with this manual as it contains important safety advice. Items and procedures are described so that you can use this unit correctly and safely. If the precautions advised are followed, this will prevent possible injury to the user and any other person.
  • Page 5 PRECAUTIONS FOR SAFE OPERATION Do not use the unit outdoors. Current leakage or electric shock may result if the unit is exposed to rain water. Only qualified engineers or service personnel should install the unit. unqualified personnel may cause electric shock or fire. Install the unit on a sturdy floor and take an adequate precaution to prevent the unit from turning over.
  • Page 6 PRECAUTIONS FOR SAFE OPERATION Ensure you do not inhale or consume medication or aerosols from around the unit at the time of maintenance. These may be harmful to your health. Never splash water directly onto the unit as this may cause electric shock or short circuit. Never put containers with liquid on the unit as this may cause electric shock or short circuit when the liquid is spilled.
  • Page 7 PRECAUTIONS FOR SAFE OPERATION Use a dedicated power source (a dedicated circuit with a breaker) as indicated on the rating label attached to the unit. A branched circuit may cause fire resulting from abnormal heating. Connect the power supply plug to the power source firmly after removing the dust on the plug. A dusty plug or improper insertion may cause a heat or ignition.
  • Page 8: Environmental Conditions

    ENVIRONMENTAL CONDITIONS This equipment is designed to be safe at least under the following conditions (based on the IEC 61010-1): 1. Indoor use; 2. Altitude up to 2000 m; 3. Ambient temperature 5 C to 40 4. Maximum relative humidity 80% for temperature up to 31 humidity at 40 5.
  • Page 9: Refrigerator Components

    REFRIGERATOR COMPONENTS MPR-1411R MPR-1411 - 46 - Rear side...
  • Page 10 The maximum storage weight for each drawer is 40 kg. Shelf (MPR-1411 only): Items to be stored in the chamber must be placed on the shelves. The maximum storage weight for each shelf is 50 kg. Do not put stored items directly onto the interior floor of the chamber.
  • Page 11: Control Panel

    REFRIGERATOR COMPONENTS Control panel 1. Door check indicator (DOOR): The red LED lamp is lit when the outer door is opened. 2. Alarm lamp (ALARM): This lamp is flashed when the audible alarm is activated. 3. Digital temperature indicator: This indicator shows the present chamber temperature or set temperature.
  • Page 12: Inside Of Front Cover

    REFRIGERATOR COMPONENTS Inside of front cover 1. Condenser filter: This filter is for prevention of condenser clogged up. Clean the filter every 3 month. 2. Remote alarm terminal: This is used to connect the unit to an exterior alarm to notify users of any malfunction.
  • Page 13: Installation Site

    INSTALLATION SITE To operate this unit properly and to obtain maximum performance, install the unit in a location with the following conditions: A location not compliance with the following conditions may cause poor performance, failure or accident. A location not subjected to direct sunlight Do not install the unit under direct sunlight.
  • Page 14: Installation

    INSTALLATION 1. Removing the packaging materials and tapes Remove all transportation packaging materials and tapes. Open the doors and ventilate the unit. If the outside panels are dirty, clean them with a diluted neutral dishwashing detergent. (Undiluted detergent can damage the plastic components. For the dilution, refer to the instruction of the detergent.) After the cleaning with the diluted detergent, always wipe it off with a wet cloth.
  • Page 15: Start-Up Of Unit

    <Attention> The outer door has a condensation on the glass during refrigerator operation. Wipe off the condensation with a dry soft cloth. Also, wipe off the water on the dew receiver regularly. C. Check the chamber temperature on the temperature...
  • Page 16: Stock Of Containers

    Exhaust air vent Do not block this vent with containers as this can impede air circulation. Items stored near the exhaust air vent can freeze when the refrigerator is operating at temperature settings lower than 5 Load line In this refrigerator, storage space is limited to allow the passage of cool air around the chamber.
  • Page 17: Chamber Temperature Setting

    CHAMBER TEMPERATURE SETTING Table 1 shows the basic procedure for setting the chamber temperature. Perform key operations in the sequence indicated in the table. The example in the table is based on the assumption that the desired temperature is 10 Note: The unit is set at the factory with a chamber temperature of 5 Table 1 Basic operation sequence (Example: Chamber set temperature 10 Description of operation...
  • Page 18: Alarm Temperature Setting

    ALARM TEMPERATURE SETTING This unit is provided with both high and low temperature alarms. The temperature at which the alarm is activated may be changed. The available set range for high temperature alarm is between +2 low temperature alarm against the chamber temperature. Note: The temperature alarm is set at Display High temperature alarm set...
  • Page 19: Setting Of Delay Of Door Alarm

    SETTING OF DELAY OF DOOR ALARM The door check indicator is light when the door is opened, and the alarm buzzer sounds with some delay to notice the door opening. The delay time (between lighting of the door check indicator and activation of the alarm buzzer) can be changed.
  • Page 20: Setting Of Alarm Resume Time

    SETTING OF ALARM RESUME TIME The alarm buzzer and remote alarm are silenced by pressing he alarm buzzer stop key (BUZZER) on the control panel during alarm condition. The buzzer and remote alarm will be activated again after certain suspension if the alarm condition is continued. procedure shown in the Table 5 below.
  • Page 21: Key Lock Function

    KEY LOCK FUNCTION This unit is provided with a key lock function. When the key lock is ON, change of temperature setting through the key pad is not available. The key lock is set in OFF at the factory. Display Key lock is OFF Key lock is ON Table 6 Procedure for key lock setting (change from key lock OFF to key lock ON)
  • Page 22: Defrost Cycles

    DEFROST CYCLES Cycle defrost When the ambient humidity is high, or a large amount of damp product is being stored inside the chamber, there is a possibility that cycle defrost may not be enough to remove all of the frost on the evaporator. In this case, a forced defrost cycle can be initiated.
  • Page 23: Alarms & Safety Functions

    ALARMS & SAFETY FUNCTIONS This unit has the alarms and safety functions shown in Table 7, and also self diagnostic functions. Table 7 Alarms and safety functions Alarm & Safety Situation High temperature If the chamber temperature deviates from the alarm set temperature +2 C or up to +14...
  • Page 24: Routine Maintenance

    ROUTINE MAINTENANCE WARNING Always disconnect the power supply to the unit prior to any repair or maintenance of the unit in order to prevent electric shock or injury. Ensure you do not inhale or consume medication or aerosols from around the unit at the time of maintenance.
  • Page 25: Replacement Of Fluorescent Lamp

    ROUTINE MAINTENANCE Replacement of fluorescent lamp The fluorescent lamp is placed vertically at the center of the chamber. Follow the procedure below to replace the lamp. 1. Turn off the fluorescent light switch and disconnect the power supply plug. 2. Remove all shelves or drawers. 3.
  • Page 26: Replacement Of Glow Starter

    ROUTINE MAINTENANCE Replacement of glow starter A glow starter is located inside the front cover. 1. Disconnect the power supply plug. 2. Remove the water-proof rubber. 3. Remove the glow starter and replace with a new one. 4. Replace the water-proof rubber. Cleaning of condenser filter 1.
  • Page 27: Troubleshooting

    Note: If the malfunction is not eliminated after checking the above items, or the malfunction is not shown in the above table, contact Sanyo sales representative or agent. Check/Remedy There is a power failure. The circuit breaker is activated.
  • Page 28: Disposal Of Unit

    DISPOSAL OF UNIT WARNING If the unit is to be stored unused in an unsupervised area for an extended period ensure that children do not have access and doors cannot be closed completely. The disposal of the unit should be accomplished by appropriate personnel. Always remove doors to prevent accidents such as suffocation.
  • Page 29 The symbol mark and recycling systems described below apply to EU countries and do not apply to countries in other areas of the world. Your SANYO product is designed and manufactured with high quality materials and components which can be recycled and/or reused.
  • Page 30 POUR LES UTILISATEURS DE UE Le symbole et les systèmes de recyclage évoqués ci-dessous s'appliquent uniquement aux pays de UE. Votre produit SANYO est conçu et fabriqué avec des composants et des matériaux de hautes qualités qui peuvent être recyclés et/ou réutilisés.
  • Page 31 PER UTENTI UE Il simbolo e i sistemi di riciclaggio descritti di seguito si applicano esclusivamente ai paesi dell’UE. Questo prodotto SANYO è stato progettato e realizzato con materiali e componenti di elevata qualità che possono essere riciclati e/o riutilizzati.
  • Page 32 Het symbool en de recycleersystemen die hieronder beschreven worden, zijn van toepassing op de landen in de EU en zijn niet van toepassing op landen in andere delen van de wereld. Uw SANYO product is ontworpen en gemaakt met materialen en onderdelen van hoge kwaliteit, die gerecycleerd en opnieuw gebruikt kunnen worden.
  • Page 33: Optional Components

    OPTIONAL COMPONENTS Automatic temperature recorder An automatic temperature recorder is available for this refrigerator as an optional accessory. If an automatic temperature recorder is required, contact your Sanyo dealer. Two recorders are selectable for the refrigerator; MTR-0621LH and MTR-G04. Please note that each recorder needs a exclusive fixture for mounting.
  • Page 34: Attachment Of Recorder Mtr-G04A

    OPTIONAL COMPONENTS 6. An attached binder (two pcs) is used for the fan cover of the top of the chamber as the Fig. 5, and a temperature sensor is fixed. 7. Route the capillary on the top of the chamber and fix it with the provided clip and screw.
  • Page 35 OPTIONAL COMPONENTS 3. Remove the black rubber caps (inside and outside) on the access port located at the top corner of the unit and take the insulation out of the access port. 4. Pass the recorder sensor into the chamber through the access port.
  • Page 36: Attachment Of Battery Kit Mpr-48B

    (MPR-48B), an optional component is necessary. A battery for power failure alarm is included in the battery kit. Contact Sanyo sales representative or agent for the installation of the battery kit (MPR-48B). 1. Remove the top cover on the right front of the refrigerator top by unscrewing 4 screws.
  • Page 37 (Fig. 6) 9. Perform the setting for battery through the keys on the control panel of refrigerator. Refer to the procedure on the next page “Setting for battery before starting” 10. Switch on the battery switch on the battery box.
  • Page 38: Setting For Battery Before Starting

    OPTIONAL COMPONENTS Setting for battery before starting Always perform the setting shown below after the installation of battery for power failure alarm, an optional component (MPR-48B). The chamber temperature and “E09” is displayed on the temperature display alternately if the battery switch is turned on without following procedure.
  • Page 39: Specifications

    Power source Rated power consumption Noise level Maximum pressure Note The unit with CE mark complies with EC directives. Pharmaceutical Refrigerator MPR-1411 W1440 x D830 x H1950 (mm) W1320 x D710 x H1500 (mm) 1364 L Painted steel Painted steel Rigid polyurethane foamed-in place 8 pcs.
  • Page 40: Safety Check Sheet

    Procedure to be adhered to in order to reduce safety risk indicated in b) below. Date : Signature : Address, Division : Telephone : Product name : Model : Pharmaceutical MPR-1411 Refrigerator MPR-1411R Please decontaminate the unit yourself before calling the service engineer. CAUTION Safety check sheet Serial number : - 77 -...
  • Page 41 SANYO Electric Co., Ltd Printed in Japan...