COPIER (Service mode for printer) > DISPLAY (State display mode) > ACC-STS
IA-RAM
1
Detail
Use Case
Adj/Set/Operate Method
Unit
Amount of Change per
Unit
■ ANALOG
COPIER (Service mode for printer) > DISPLAY (State display mode) > ANALOG
TEMP
1
Detail
Use Case
Display/Adj/Set Range
Default Value
HUM
1
Detail
Use Case
Display/Adj/Set Range
Default Value
FIX-C
1
Detail
Use Case
Display/Adj/Set Range
Unit
Default Value
FIX-E
1
Detail
Use Case
Display/Adj/Set Range
Unit
Default Value
FIX-E2
1
Detail
Use Case
Display/Adj/Set Range
Default Value
Dspl of MNCON PCB 1 DDR2-SDRAM capacity
To display the memory (DDR2-SDRAM) capacity of the Main Controller PCB 1.
When checking the memory capacity of the Main Controller PCB
N/A (Display only)
MB
1
Display of inside temperature
To display the temperature inside the machine detected by Environment Sensor.
When checking the temperature inside the machine
0 to 60
0
Display of inside humidity
To display the humidity inside the machine detected by Environment Sensor.
When checking the humidity inside the machine
0 to 100
0
Dspl of Fixing Roller center temperature
To display the center temperature of the Fixing Roller detected by the Fixing Main Thermistor.
When checking the temperature at the center of Fixing Roller
0 to 999
deg C
0
Dspl of Fixing Roller edge temperature
To display the edge temperature of the Fixing Roller detected by the Fixing Sub Thermistor 1.
Fixing Sub Thermistor 1 is located in the drive side of Fixing Roller.
When checking the edge temperature of the Fixing Roller
0 to 999
deg C
0
Dspl of Fixing Roller edge temperature
To display the edge temperature of the Fixing Roller detected by the Fixing Sub Thermistor 2.
Fixing Sub Thermistor 2 is located in the non-drive side of Fixing Roller.
When checking the edge temperature of the Fixing Roller
0 to 999
0
374
8. Service Mode