Alarm
Title
Code
04-0003
Cassette 3 Lifter error Movement: The Cassette 3 Lifter Motor (M20) is stopped. Not
Cause: The Cassette Lifter does not rise, failure of the Cassette
3 Paper Height Sensor (PS17).
Measures:
1. Turn OFF and then ON the power.
When it is recovered, the measure is completed. If it is not
recovered, execute the following measures.
2. Check if the Deck Lifter rises.
If not, execute the following measures. If an alarm occurs
although it rises, execute step 5 and later steps.
3. Check the connection between the Cassette 3 Lifter Motor
(M20) and the Feed Driver PCB (PCB3).
Motor side: J2072, PCB side: J225
4. Replace the Cassette 3.
5. Check the connection between the Cassette 3 Paper Height
Sensor (PS17) and the Feed Driver PCB (PCB3).
Sensor side: J2080, J3635 (relay), PCB side: J223
6. Check the operation of the Cassette 3 Paper Height Sensor
(PS17), and replace it if necessary.
7. Replace the Feed Driver PCB (PCB3).
04-0004
Cassette 4 Lifter error Movement: The Cassette 4 Lifter Motor (M21) is stopped. Not
Cause: The Cassette 4 Lifter does not rise, failure of the
Cassette 4 Paper Height Sensor (PS18).
Measures:
1. Turn OFF and then ON the power.
When it is recovered, the measure is completed. If it is not
recovered, execute the following measures.
2. Check if the Deck Lifter rises.
If not, execute the following measures. If an alarm occurs
although it rises, execute step 5 and later steps.
3. Check the connection between the Cassette 4 Lifter Motor
(M21) and the Feed Driver PCB (PCB3).
Motor side: J2074, PCB side: J225
4. Replace the Cassette 4.
5. Check the connection between the Cassette 4 Paper Height
Sensor (PS18) and the Feed Driver PCB (PCB3).
Sensor side: J2091, J3636 (relay), PCB side: J224
6. Check the operation of the Cassette 4 Paper Height Sensor
(PS18), and replace it if necessary.
7. Replace the Feed Driver PCB (PCB3).
7
Error Code > Alarm Code > List of Alarm Code
A. movement /B. cause /C. measures
using the Cassette 3.
using the Cassette 4.
7
Error Code > Alarm Code > List of Alarm Code
Alarm
Title
Code
04-0008
Option Deck Lifter
Movement: The Option Deck Pickup Motor (M) is stopped. Not
error
Cause: The Option Deck does not rise, failure of the Option
Deck Paper Height Sensor (PS).
Measures: Clear the error by turning OFF/ON the power.
04-0010
Jam left untouched
-
(RDS creates)
04-0031
Right Deck Lifter
Movement: The Right Deck Lifter Motor (M4) is stopped. Not
Motor overcurrent
alarm
Cause: The Right Deck is above the upper limit or is stopped
along the way.
Measures:
1. Check the connection between the Right Deck Lifter Motor
(M4) and the Feed Driver PCB (PCB3).
Motor side: J2069, PCB side: J225
2. Replace the Right Deck Lifter Motor (M4).
3. Check the Right Deck Upper Limit Sensor (PS8).
4. Check the Right Deck Lifter Gear (damage, foreign matter,
etc.).
5. Replace the Feed Driver PCB (PCB3).
04-0032
Left Deck Lifter Motor
Movement: The Left Deck Lifter Motor (M5) is stopped. Not
overcurrent alarm
Cause: The Left Deck is above the upper limit or is stopped
along the way.
Measures:
1. Check the connection between the Left Deck Lifter Motor
(M5) and the Feed Driver PCB (PCB3).
Motor side: J2069, PCB side: J225
2. Replace the Left Deck Lifter Motor (M5).
3. Check the Left Deck Upper Limit Sensor (PS12).
4. Check the Left Deck Lifter Gear (damage, foreign matter,
etc.).
5. Replace the Feed Driver PCB (PCB3).
A. movement /B. cause /C. measures
using the Left Deck.
using the Right Deck.
using the Left Deck.
7-94