CCS Technical Documentation
All regulators can be controlled individually with 2.78V logic directly or through control
register.
Use of the regulators can be seen in the power distribution diagram. VrefRF01 is used as
the reference voltages for the RX ADC`s reference in Mjoelner.
The regulators are connected to Mjoelner, either directly or through output loading net-
works. The individual regulator can be switched on/off through the serial data bus in
order to reduce the power consumption.
List of the needed supply voltages:
Volt. source
VR1a
VR2
VR3
VR4
VR5
PLL_prescaler-PLL_counters)
VR6
VR7
VrefRF01
VrefRF02
VIO
Vbatt
Typical current consumption
The table shows the typical current consumption in different operation modes.
Operation mode
Power OFF
Issue 1 11/02
Load
Mjoelner, charge pump
Mjoelner, VTX (TX modulator, BB_buffer)
Mjoelner, VXO (VCXO - digital logic)
Not used
Mjoelner, VPLL (Dividers - lo_buffers - PLL_charge –
Mjoelner, VRX (Front_end LNA- Pre_gain – BB section)
VCO module
Mjoelner, VREF1 (ref. Voltage)
Not used
Mjoelner, VBB (Dig_com)
PA
Table 37:
Typical current consumption
Current Con-
sumption
< 10uA
ãNokia Corporation
System Module & UI
Notes
Leakage current (dual PA)
RH-9