e. Add a 'udev' rule for the NIC renaming, by adding the following line to the
file '/etc/udev/rules.d/70-persistent-ipoib.rules:
ACTION=="add", SUBSYSTEM=="net", DRIVERS=="?*",
ATTR{type}=="1", ATTR{address}=="24:6e:96:42:3f:a4",
NAME="sio_mgmt"
f. Rename the ifcfg script file by running the command:
mv /etc/sysconfig/network-scripts/ifcfg-{eno3,sio_mgmt}
g. Edit the ifcfg script file by running the command:
sed 's/eno3/sio_mgmt/g' /etc/sysconfig/network-scripts/
ifcfg-sio_mgmt
h. After renaming all the NICs, reboot the SVM using the shutdown/reboot
procedure to apply the changes.
14. Update the Virtual IP Interface name in ScaleIO:
a. From the VxFlex OS CLI (SCLI), run:
scli --query_cluster
b. Log all the IDs of the MDMs. (Master MDM, Slave MDMs and Standby
MDMs)
c. For each MDM, run the following VxFlex OS CLI (SCLI) command:
scli --modify_virtual_ip_interfaces --target_mdm_id
<MDM_ID> --new_mdm_virtual_ip_interface sio_d_1,sio_d_2
15. From a command line on the AMS server, run this AMS CLI command:
Operating
Command to run
System of
AMS server
Windows
C:\Program Files\EMC\scaleio\AMS\webapps\ROOT
\resources\scaleio_repository
ams-cli-<VERSION>.jar --username admin --password
<ADMIN_PASSWORD> --take_ownership --mdm_ips
<MDM_IP_ADDRESSES> --mdm_username admin --
mdm_password <MDM_PASSWORD> --monitor_username
<MONITOR_USER_NAME> --monitor_password
<MONITOR_PASSWORD>
Linux
/opt/emc/scaleio/ams/webapps/ROOT/resources/
scaleio_repository/scaleio_repository
ScaleIO-ams-cli-<VERSION>.jar --username admin --
password <ADMIN_PASSWORD> --take_ownership --mdm_ips
<MDM_IP_ADDRESSES> --mdm_username admin --
mdm_password <MDM_PASSWORD> --monitor_username
java -jar EMC-ScaleIO-
java -jar EMC-