hit counter script

Dell EMC VxFlex Ready Node User Manual page 303

Hide thumbs Also See for EMC VxFlex Ready Node:
Table of Contents

Advertisement

Alert Message in
Alert Message in
VxFlex OS GUI
REST
RFcache API
RFCACHE_API_ERROR
mismatch
_MISMACH
SDS is in
SDS_IN_MAINTENANC
Maintenance Mode
E
Device failed
DEVICE_FAILED
Device test is done
DEVICE_PENDING_ACT
and device is
IVATION
pending activation
Device has fixed
FIXED_READ_ERROR_
read errors
COUNT_ABOVE_WARN
ING_THRESHOLD
Device has fixed
FIXED_READ_ERROR_
read errors
COUNT_ABOVE_CRITI
CAL_THRESHOLD
Device failed: All IO
DEVICE_ERROR_ERRO
to the device will be
R
stopped, and data
will be relocated to
another device.
Device failed: All IO
DEVICE_ERROR_WARN
to the device will be
ING
stopped, and data
Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert
Message in
SNMP Trap
SDS.SDS.RFCA
CHE_API_ERR
OR_MISMACH
SDS.SDS.SDS_
IN_MAINTENA
NCE
SDS.Device.De
vice_Failed
SDS.Device.De
vice_Pending_
Activation
SDS.Device.FIX
ED_READ_ERR
OR_COUNT_A
BOVE_WARNI
NG_THRESHO
LD
SDS.Device.FIX
ED_READ_ERR
OR_COUNT_A
BOVE_CRITICA
L_THRESHOLD
SDS.Device.De
vice_ErrorError
SDS.Device.De
vice_ErrorWarn
ing
Alert Code
Severity
(for ESRS)
SIO03.01.000
2 (Warning)
0013
SIO03.01.000
2 (Warning)
0014
SIO03.02.000
3 (Error)
0001
SIO03.02.000
2 (Warning)
0002
SIO03.02.000
3 (Error) if
0003
counter > 0
SIO03.02.000
5 (Critical) if
0004
counter >= 5
SIO03.02.000
5 (Critical)
0005
SIO03.02.000
3 (Error)
0006
Dell EMC VxFlex Ready Node AMS User Guide
SNMP Trap Support
Recommended Action
The Read Flash Cache
(xcache) driver version and
SDS version do not match.
Try to upgrade them to the
same version. If the
problem persists, contact
Customer Support.
The SDS is currently in
Maintenance Mode. Exit
Maintenance Mode once
maintenance is complete. If
an NDU is in progress,
ignore this warning.
The SDS device could not
be opened, read from or
written to. Validate the
device state. Check the
cause of the error, and
determine if it is a human
error or a system
malfunction. Check
hardware if needed.
The SDS device has been
added and tested. Activate
the SDS device.
Read from the SDS device
failed. Data was corrected
from the other copy. No
action is required, but note
that the device might be
faulty.
SDS device read failed
more than 5 times. Replace
the physical device.
Check the device, and if
necessary, replace it
Check the device, and if
necessary, replace it
303