Alert Message in
Alert Message in
VxFlex OS GUI
REST
The Logical Disk IO
LOGICAL_DISK_INVALI
policy is not
D_WRITE_BACK_POLIC
Configured properly
Y
(Write-Back)
Logical Disk access
LOGICAL_DISK_INVALI
mode is not set to
D_ACCESS_MODE
"Read-Write"
The Logical Disk
LOGICAL_DISK_INVALI
RAID level is not set
D_RAID_LEVEL
to RAID0
Logical Disk caching
LOGICAL_DISK_INVALI
policy is not set to
D_CACHE_POLICY
"DirectIO"
Logical disk is no
LOGICAL_DISK_NO_LO
longer being cached
NGER_CACHED
The state of the
BATTERY_INVALID_ST
backup battery in
ATE
the storage
controller is not
optimal
The backup battery
BATTERY_REPLACEME
in the storage
NT_REQUIRED
controller needs to
be replaced
The storage
BATTERY_INVALID_TE
controller battery
MPERATURE
temperature is not
within the
configured threshold
Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert
Message in
SNMP Trap
Storage_Contr
oller.Logical_Di
sk.INVALID_W
RITE_BACK_P
OLICY
Storage_Contr
oller.Logical_Di
sk.INVALID_AC
CESS_MODE
Storage_Contr
oller.Logical_Di
sk.INVALID_RA
ID_LEVEL
Storage_Contr
oller.Logical_Di
sk.INVALID_CA
CHE_POLICY
Storage_Contr
oller.Logical_Di
sk.LOGICAL_DI
SK_NO_LONG
ER_CACHED
Storage_Contr
oller.Battery.Inv
alid_State
Storage_Contr
oller.Battery.RE
PLACEMENT_
REQUIRED
Storage_Contr
oller.Battery.IN
VALID_TEMPE
RATURE
Alert Code
Severity
(for ESRS)
SIO06.02.00
3 (Error)
00002
SIO06.02.00
5 (Critical)
00003
SIO06.02.00
3 (Error)
00004
SIO06.02.00
3 (Error)
00005
SIO06.02.00
3 (Error)
00006
SIO06.03.00
5 (Critical) 3
00001
(Error)
SIO06.03.00
5 (Critical)
00002
SIO06.03.00
3 (Error)
00003
Dell EMC VxFlex Ready Node AMS User Guide
SNMP Trap Support
Recommended Action
Check the Raid controller
battery status, a fault in the
battery will impact the
Write-Back functionality.
Access the storage
controller and change the
logical disk's access mode
to "Read-Write".
The RAID type is set in the
storage controller is
incorrect. Access the
storage controller, verify
that the Logical Disk does
not contain any data that is
not backed-up, destroy the
Logical Disk, and re-create
the logical disk as RAID0.
Access the storage
controller, and change the
RAID0 caching policy for
the Logical Disk to
"DirectIO".
Disable the Physical Drive
physical cache. Note: This
may cause DI issues in
power cycle scenarios.
The backup battery is not
fully charged, but it will
recharge itself while the
storage controller is
powered on.
The backup battery in the
storage controller may be
nearing the end of its
working life. Replace the
battery.
Check the temperature in
the server and at the data
center. Check if a fan alert
is raised in the node. Check
the battery and the RAID
controller and replace faulty
items.
305