SNMP Trap Support
Alert Message in
Alert Message in
VxFlex OS GUI
REST
Logical Disk caching
LOGICAL_DISK_INV
policy is not set to
ALID_CACHE_POLI
"DirectIO"
CY
Logical disk is no
LOGICAL_DISK_NO
longer being cached
_LONGER_CACHE
D
The state of the
BATTERY_INVALID
backup battery in
_STATE
the storage
controller is not
optimal
The backup battery
BATTERY_REPLAC
in the storage
EMENT_REQUIRED
controller needs to
be replaced
The storage
BATTERY_INVALID
controller battery
_TEMPERATURE
temperature is not
within the
configured
threshold
There is no backup
BATTERY_NOT_PR
battery installed in
ESENT
the storage
controller
The storage
BATTERY_INVALID
controller contains
_PACK_ENERGY
an incompatible
battery pack
RAID controller's
BATTERY_INVALID
battery has invalid
_VOLTAGE
voltage state
Hypervisor boot
BOOT_DRIVE_INVA
drive state is not OK
LID_STATE
Dell EMC VxFlex Ready Node AMS User Guide
314
Table 35 VxFlex Ready Node–specific Alerts in SNMP, VxFlex OS GUI, REST, and
ESRS (continued)
Alert Message in
SNMP Trap
Storage_Controller.
Logical_Disk.INVALI
D_CACHE_POLICY
Storage_Controller.
Logical_Disk.LOGIC
AL_DISK_NO_LON
GER_CACHED
Storage_Controller.
Battery.Invalid_Stat
e
Storage_Controller.
Battery.REPLACEM
ENT_REQUIRED
Storage_Controller.
Battery.INVALID_TE
MPERATURE
Storage_Controller.
Battery.NOT_PRES
ENT
Storage_Controller.
Battery.Invalid_Pac
k_Energy
Storage_Controller.
Battery.Invalid_Volt
age
Node.Boot_Drive.In
valid_State
Alert Code
Severity
(for ESRS)
SIO06.02.000
3 (Error)
0005
SIO06.02.000
3 (Error)
0006
SIO06.03.000
5 (Critical)
0001
3 (Error)
SIO06.03.000
5 (Critical) The backup battery in the
0002
SIO06.03.000
3 (Error)
0003
SIO06.03.000
5 (Critical) Install a backup battery in the
0004
SIO06.03.000
3 (Error)
0005
SIO06.03.000
3 (Error)
0006
SIO07.01.000
3 (Error)
0001
Recommended Action
and re-create the logical disk
as RAID0.
Access the storage
controller, and change the
RAID0 caching policy for the
Logical Disk to "DirectIO".
Disable the Physical Drive
physical cache. Note: This
may cause DI issues in power
cycle scenarios.
The backup battery is not
fully charged, but it will
recharge itself while the
storage controller is powered
on.
storage controller may be
nearing the end of its working
life. Replace the battery.
Check the temperature in the
server and at the data center.
Check if a fan alert is raised
in the node. Check the
battery and the RAID
controller and replace faulty
items.
storage controller.
Replace the storage
controller battery with one
that is compatible with your
controller's model.
Check the RAID controller's
battery. It may need to be
replaced.
The drive on which the ESXi
hypervisor is installed has
reported an error. Replace
the drive and reinstall the
ESXi on the new drive.