hit counter script

Sanyo C3082 Technical & Service Manual page 13

Dc inverter split system air conditioner
Hide thumbs Also See for C3082:
Table of Contents

Advertisement

2-2-2. Outdoor Unit
C3082
Outdoor Unit
P.C.Board
Part No.
Controls
Circuit Fuse
Compressor
Type
Compressor Model / Nominal Output
Compressor Oil ... Amount
Coil Resistance (Ambient Temp. 77 °F (25 °C))
Safety Device
CT (Peak current cut-off control)
Compressor Discharge Temp. Control
Operation cut-off control in abnormal ambient Temp.
Overload Relay
Run Capacitor
Crankcase Heater
Fan
Type
Q'ty ... Dia.
Fan Motor
Type
Model ... Q'ty
No. of Poles
Rough Measure RPM (Cool)
Nominal Output
Coil Resistance
(Ambient Temp. 68 °F (20 °C))
Safety Device
Type
Over- Current Protection
Over- Heat Protection
Run Capacitor
Heat Exchanger Coil
Coil
Rows
Fins per inch
Face Area
External Finish
Control P.C.B
CR-C3082-F
Microprocessor
400V 3.5A
Pints (cc)
Ohm
Model
Operation Temp.
Micro F
VAC
inch (mm)
W
Ohm
Micro F
VAC
ft
(m
)
2
2
13
Noise Filer P.C.B
POW-CH3082-B1
-
250V 25A
DC Twin Rotary (Hermetic)
C-9RVN273H0H / 2,250W
FV68S ... 2.98 (1,400)
T - R :
0.169
T - S :
0.169
R - S :
0.169
Yes
Yes
Yes
CS-7L110
Open : 230 °F (110 °C), Close : 203 °F (95 °C)
-
-
230V 30W
Propeller
1 ... D19-9/32 (D490)
DC Motor
SIC-71FW-D8120-4A ... 1
8
750
142
-
Internal Controller
Yes
Yes
-
-
Aluminum Plate Fin / Copper Tube
2
21.2
8.05 (0.748)
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
H.I.C.Board
HIC-CH3072R-C1
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C3682Ks3082Ks3682

Table of Contents