1.2.3

Adjusting the Mechanical Systems

The machine's mechanical systems do not require adjustments.
1.2.4

Adjusting the Electrical Systems

1.2.4.1 Contact Sensor LED Intensity Auto Adjustment

Check to make sure that the copyboard cover (ADF) is fully closed before
making these adjustments.
Execute auto adjustment of the contact sensor LED intensity as follows:
1) Press the User Mode key and the # key to start service mode.
2) Press the Left/Right Arrow key so that 'TEST MODE' is indicated.
3) Press the OK key.
4) Press '2' on the keypad so that 'TEST MODE' is indicated.
5) Press '7' on the keypad to clear the CCD parameter.
6) Press the Stop key to return to 'TEST MODE'.
7) Press '2' on the keypad so that '2: CCD TEST' is indicated.
8) Press '8' on the keypad so that the machine starts contact sensor LED auto adjustment.
9) End the work when the LCD display indicates 'OK'; if it indicates 'NG', on the other
hand, start over.
10) Press the Stop key and the User Mode key (to end TEST MODE).