hit counter script
Download Print this page

Making Pre-Checks; Selecting The Site Of Installation - Canon LASER CLASS 810 Service Manual

Hide thumbs Also See for LASER CLASS 810:

Advertisement

2.1 Making Pre-Checks

2.1.1 Selecting the Site of Installation

Select the site of installation against the following requirements; if possible, visit the user's before delivery of the machine:
1) There must be a power outlet properly grounded and rated as indicated (-/+10%) for exclusive use by the machine.
2) The environment of the room must be as indicated in the following diagram, and the machine must not be installed near a water faucet, water boiler, humidifier,
or refrigerator:
<Environmental zone assured>
[A]: Zone A: Satisfies all the conditions of the standard image quality and paper feed performance.
[B]: Zone B: Inferior to Zone A in terms of the standard image quality and paper feed performance, or may not apply.
[C]: Zone C: Problems associated with safety, malfunctions, or incorrect message display do not occur, but image quality and paper feed performance are
not guaranteed.
3) The machine must not be installed near a source of fire or in an area subject to dust or ammonium gas.
If the area is exposed to direct rays of the sun, provide curtains to the window.
4) The level of ozone generated by the machine will not affect the health of individuals around it. Some, however, may find its odor unpleasant as while remaining
in contact with it for long hours. Be sure that the room is well ventilated.
5) The floor of the machine must be level so that the feet of the machine will remain in contact and the machine will remain level.
6) The machine must be at least 10 cm away from any wall, permitting unobstructed use.
(%RH)
100
[C]
90
80
70
[B]
50
20
10
0
5
10
with the handset installed
[A]
15
20
25
30
27.5
F-2-1
100 mm min.
897 mm
F-2-2
35
40
(degC)
Chapter 2
0016-7375
2-1

Advertisement

loading

This manual is also suitable for:

Laser class 830i