VIII. Servicing Notes
A.

Power and Plug Requirements

Canon USA Inc. strongly suggests dedicated and properly grounded outlets be
provided for these imageRUNNER ADVANCE DX Devices.
The imageRUNNER ADVANCE DX C5700 Series Main Unit requires a
dedicated single phase 120V/20A NEMA 5-20R receptacle for proper operation
The imageRUNNER ADVANCE DX C5760i / C5750i Main Units require a
dedicated single-phase 120V/20A NEMA 5-20R receptacle for proper
operation.
The imageRUNNER ADVANCE DX C5740i / C5735i Main Units require a
dedicated single-phase 120V/15A NEMA 5-15R receptacle for proper
operation.
Table 14 – Power Receptacle
imageRUNNER ADVANCE DX
C5760i / C5750i Main Unit
IMPORTANT
We recommend an additional standard 120 V/15 A NEMA 5-15 outlet for
service tools, such as a laptop computer or vacuum that may be used when
servicing or configuring the machine.
Use only dedicated and properly grounded outlets for the main unit. It is
also strongly suggested to use dedicated and properly grounded outlets for
each optional accessory. Do not use extension cords. The ground
connection serves to provide the internal electronics with a reference
voltage. Faulty or poor ground sources will cause this reference voltage to
fall into a range that no longer serves as a reliable reference voltage. The
internal logic and programming of the imageRUNNER ADVANCE DX
machines will not perform reliably if there is an insufficient difference
between the internal operating signal voltages and the poor ground
reference signal. A qualified electrician can measure and provide the
ground source that the imageRUNNER ADVANCE DX machines or any
computer controlled office equipment requires.
Before installation, confirm that all necessary receptacles are available.
Phase converters and step down transformers are not supported
imageRUNNER ADVANCE DX C5700 Series Service Guide
Revision 5
imageRUNNER ADVANCE DX C5700 Series Service Guide
NEMA 5-20 Receptacle
imageRUNNER ADVANCE DX
C5740i / C5735i Main Unit
NEMA 5-15 Receptacle
March 2021
Page 42