hit counter script

Removing The Expansion Card Risers - Dell PowerEdge R250 VN927 Installation And Service Manual

Table of Contents

Advertisement

Figure 49. Butterfly riser
1. Slot 2
2. Slot 1
NOTE:
The expansion-card slots are not hot-swappable.
For a proper mechanical fit and proper cooling of expansion cards, follow the guidelines in the following table. The expansion
cards with the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be
installed in the card priority and slot priority order.
Table 21. Configuration 0: Butterfly riser
Card type
Internal PERC adapter
Dell External Adapter
Broadcom (NIC: 1Gb)
Intel (NIC: 1Gb)
Dell BOSS S1 Module
NOTE:
No expansion cards are supported in the "no riser" configuration.

Removing the expansion card risers

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the air
shroud.
Steps
1. Open the blue expansion card riser retention-latch located on the system.
2. Holding the blue touch points, lift the expansion card riser out of the system.
3. If you are not replacing the expansion card, install a filler bracket and close the card retention latch.
56
Installing and removing system components
Slot priority
2
1, 2
1, 2
1, 2
1, 2
Safety
instructions.
Before working inside your
Maximum number of cards
1
2
2
2
2
system.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emc poweredge r250

Table of Contents