hit counter script

Error Code; Error Code Details - Canon imageRUNNER ADVANCE DX C477 Service Manual

Table of Contents

Advertisement

Error Code

Error Code Details

E000-0001-05
Detection Description
Remedy
E001-0001-05
Detection Description
Remedy
Fixing Assembly: Temperature rise failure
The Fixing Assembly did not reach the specified temperature within the specified time at power-
on.
[Related parts]
- Fixing Drawer Harness (between the Fixing Drawer Connector J-86 and the Connector J154 of
the DC Controller PCB)
- Fixing Assembly
- DC Controller PCB(UN04)
- Low Voltage Power Supply PCB
[Remedy]
- Disconnect and then connect the Fixing Assembly. In addition, check the Connector J 86 that
connects the Fixing Assembly to the host machine and replace the Connector Assembly or the
Fixing Assembly if the connector is damaged.
- Disconnect and then connect the Connector J154 on the DC Controller PCB.
- Replace the Fixing Assembly.
- Replace the Low-voltage Power Supply PCB.
[Reference]
- Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and
restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Fixing Main Thermistor high temperature detection error
The Fixing Main Thermistor temperature rose higher than the specified level.
[Related parts]
- Fixing Drawer Harness (between the Fixing Drawer Connector J86 and the Connector J154 of
the DC Controller PCB)
- Fixing Assembly
- DC Controller PCB(UN04)
- Low Voltage Power Supply PCB
[Remedy]
- Disconnect and then connect the Fixing Assembly. In addition, check the Connector J86 that
connects the Fixing Assembly to the host machine and replace the Connector Assembly or the
Fixing Assembly if the Connector is damaged.
- Replace the Fixing Assembly.
- Replace the Low-voltage Power Supply PCB.
[Reference]
- Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and
restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
366
8. Error/Jam/Alarm

Advertisement

Table of Contents
loading

Table of Contents

Save PDF