APPENDIX 3 FIRMWARE SWITCHS (WSW)
Selector
No.
1
2
3
4
5
6
7-8
l
Selectors 1 through 4:
If the machine detects the OFF state of calling signal (Ci) for a time length which is greater
than the value set by selectors 1 and 2 and less than the value set by selectors 3 and 4, it
interprets the Ci signal as OFF.
l
Selectors 5 and 6: Detecting time setting
These selectors set the time length required to make the machine acknowledge itself to be
called. That is, if the machine continuously detects calling signals with the frequency set by
selectors 1 through 4 of WSW14 during the time length set by these selectors 5 and 6, it
acknowledges the call.
WSW12 (Signal detection condition setting)
Function
Min. OFF time length of calling
signal (Ci)
Max. OFF time length of calling
signal (Ci)
Detecting time setting
Not used.
Min. and max. OFF time length of calling signal (Ci)
Setting and Specifications
No. 1
2
0
0
0
1
1
0
1
1
No. 3
4
0
0
0
1
1
0
1
1
No. 5
6
0
0
0
1
1
0
1
1
A-18
:
1500 ms
:
500 ms
:
700 ms
:
900 ms
:
6 sec.
:
7 sec.
:
9 sec.
:
11 sec.
:
800 ms
:
200 ms
:
250 ms
:
150 ms