Selector
No.
1
Maximum OGM recording time
2
Time length from CML ON
3
to start of pseudo ring
4
backtone transmission
Attenuator for playback of
5
ICM/OGM to the line
|
(Selectable from the range of
8
0-15 dB)
l
Selectors 1 and 2: Maximum OGM recording time
These selectors set the allowable maximum recording time for an OGM.
l
Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission
These selectors set the length of time from CML-ON up to the start of pseudo ring backtone
transmission.
In models with OGM facilities, the settings made by these selectors also apply to the length of time
from CML-ON up to the start of OGM transmission.
l
Selectors 5 through 8:
Setting two or more selectors to "1" produces addition of attenuation assigned to each selector.
This setting is not limited by selector 8 of WSW23.
WSW24
Function
Attenuator for playback of ICM/OGM to the line
App. 4-27
(TAD setting 2)
Setting and Specifications
No.
1
2
0
0
:
0
1
:
1
0
:
1
1
:
No.
3
4
0
0
:
0
1
:
1
0
:
1
1
:
0:
0 dB
0:
0 dB
0:
0 dB
0:
0 dB
15 sec.
20 sec.
30 sec.
50 sec.
4 sec.
3 sec.
2 sec.
1 sec.
1:
8 dB
1:
4 dB
1:
2 dB
1:
1 dB
Confidential