Low voltage power circuit carries the overcurrent preventive function against and overvoltage preventive function that block the voltage output automatically to
prevent the power circuit brokerage when the overcurrent or overvoltage occur due to load errors such as short circuit etc.
Thus, when the DC power cannot be output from the low voltage circuit, the protective function against overcurrent or overvoltage may be working. Turn OFF the
power switch (SW1) to fix load errors and turn ON the switch again (see note 1).
Also the circuit carries the 2 fuses (FU101, FU102) as a preventive function (see note 2). The fuses blow to block the power supply when overcurrent occurs in AC
line.
1. When restoring the low voltage power after protective function is activated, leave it for 2 minutes or more from turning off the switch or plugging out before turning