9. CLEANING

9-2. Cleaning the control box air inlet ports

9-3. Draining the oil

9-4. Cleaning the eye guard

9-5. Checking the needle

9-6. Lubrication

Lubricate the sewing machine while referring to "3-16. Lubrication".
52
Use a vacuum cleaner to clean the filter in the air inlet ports
(2) of the control box (1) at least once a month.
4483Q
1. Remove and empty the waste oil tank (1) whenever it is
full.
2. After emptying the waste oil tank (1), screw it back into
its original position.
2550Q
Wipe the eye guard clean with a soft cloth.
NOTE:
Do not use solvents such as kerosene or thinner to clean
the eye guard.
4987Q
Always check that the tip of the needle is not broken and
also that the needle is not bent before starting sewing.
4988Q
BAS-311G, BAS-326G