Chapter 2
2.5 Detection Functions with Sensors
2.5.1 Sensors for covers
0023-2554
iPF750 / iPF755
Ink Tank Cover Switch (L)
Ink Tank Cover Switch (R)
Upper Cover Lock Solenoid
F-2-38
Upper cover lock switch
The microswitch-based upper cover lock switch detects the open/closed states of the upper cover.
When the upper cover close, the switch is pressed to detect the closed state of the upper cover.
Ink tank cover switch (L)/(R)
The microswitch-based ink tank cover switches detect the open/closed states of left and right ink tank cover.
When an ink tank cover closes, the switch is pressed to detect the closed state of the ink tank cover.