Mitsubishi Electric PKFY-PVBM-E Operation Manual
Mitsubishi Electric PKFY-PVBM-E Operation Manual

Mitsubishi Electric PKFY-PVBM-E Operation Manual

City multi air-conditioners for building application
Hide thumbs Also See for PKFY-PVBM-E:

Advertisement

Air-Conditioners For Building Application

INDOOR UNIT

PKFY-P·VBM-E / PKFY-P·VHM-E
PCFY-P·VKM-E / PFFY-P·VKM-E2 / PMFY-P·VBM-E
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du
climatiseur.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de
airconditioner gebruikt.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado
para garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro
della stessa.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a uni-
dade de ar condicionado.
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
VOOR DE GEBRUIKER
PARA EL USUARIO
PER L'UTENTE
PARA O UTILIZADOR
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)
Italiano (I)
Português (P)
Türkçe (TR)

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PKFY-PVBM-E

  • Page 1: Indoor Unit

    Air-Conditioners For Building Application INDOOR UNIT PKFY-P·VBM-E / PKFY-P·VHM-E PCFY-P·VKM-E / PFFY-P·VKM-E2 / PMFY-P·VBM-E OPERATION MANUAL FOR USER English (GB) For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH FÜR BENUTZER Deutsch (D) Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2: Table Of Contents

    Contents 1. Safety Precautions ..............2 5. Emergency Operation for Wireless Remote-controller ..10 2. Parts Names ................3 6. Care and Cleaning..............11 3. Operation ................7 7. Troubleshooting ..............13 4. Timer..................10 8. Specifications ...............15 Note: If you need any information for the other remote controller, please refer to the instruction book included in this box. 1.
  • Page 3: Parts Names

    2. Parts Names Indoor Unit PKFY-P·VBM-E PKFY-P·VHM-E PCFY-P·VKM-E PMFY-P·VBM-E PFFY-P·VKM-E2 Fan speed 4 speed 3 speed+ Auto* 4 speed+ Auto* 4 speed 4 speed Steps 4 steps 5 steps 5 steps 4 steps 4 steps Vane Auto swing Louver Manual Manual Manual Manual...
  • Page 4: Controller Interface

    2. Parts Names Controller interface The functions of the function buttons change depending on the screen. Refer to the button function guide that appears at the bottom of the LCD for the functions they serve on a given screen. that corresponds to the locked button will not appear. Main display Main menu Main...
  • Page 5 2. Parts Names Display The main display can be displayed in two different modes: “Full” and “Basic”. The factory setting is “Full”. To switch to the “Basic” mode, change the setting on the Main display setting. (Refer to operation manual included with remote controller.) <Full mode>...
  • Page 6 2. Parts Names Transmission area Transmission indicator Remote controller display Timer indicator * For explanation purposes, all of the items that appear in the display are shown. * All items are displayed when the Reset button is pressed. Operation areas ON/OFF button Set Temperature buttons Fan Speed button (Changes fan speed)
  • Page 7: Operation

    About the operation method, refer to the operation manual that comes with each remote controller. [ON] [OFF] Press the [ON/OFF] button. Press the [ON/OFF] button again. The ON/OFF lamp will light up in The ON/OFF lamp will come off, green, and the operation will start. and the operation will stop.
  • Page 8 Note: The number of available fan speeds depends on the type of unit connected. Note also that some units do not provide an “Auto” setting. Preset temperature In the following cases, the actual fan speed generated by the unit will differ for cooling from the speed shown the remote controller display.
  • Page 9 <Navigating through the pages> <Vane setting> page Press the [F1] or [F2] button to go Main Main menu Vane·Louver·Vent. (Lossnay) through the vane setting options: Press [F3] to go to the previous High power Swing "Auto", "Step 1", "Step 2", "Step 3", Timer page.
  • Page 10: Timer

    <[Manual] To Change the Airflow's Left/Right Direction> * The louver button cannot be used. For LOSSNAY combination The following 2 patterns of operation is available. and adjust to the desired direction. * Do not set to the inside direction when the unit is in the cooling or drying mode because there is a risk of Note: (for wireless remote controller) condensation and water dripping.
  • Page 11: Care And Cleaning

    6. Care and Cleaning Filter information will appear on the Main display When the is displayed on the in the Full mode when it is time to Main display in the Full mode, the Room Room system is centrally controlled and Cool Set temp.
  • Page 12 6. Care and Cleaning PCFY-P·VKM-E PFFY-P·VKM-E2 1 Open the intake grille. 2 Hold the knob on the filter then pull the filter up in the direction of an arrow. To replace the filter after cleaning, be sure to insert the filter far enough until it fits into the stopper.
  • Page 13: Troubleshooting

    7. Troubleshooting Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. Clean the filter. (Airflow is reduced when the filter is dirty or clogged.) Check the temperature adjustment and adjust the set temperature. Make sure that there is plenty of space around the outdoor unit.
  • Page 14 7. Troubleshooting Having trouble? Here is the solution. (Unit is operating normally.) Noise is louder than specifications. The indoor operation sound level is affected by the acoustics of the particular room as shown in the following table and will be higher than the noise specification, which was measured in an echo-free room.
  • Page 15: Specifications

    8. Specifications PCFY-P·VKM-E Model P100 P125 Power source (Voltage/Frequency) <V/Hz> ~/N 220-230-240/50, 220/60 Capacity (Cooling/Heating) <kW> 4.5/5.0 7.1/8.0 11.2/12.5 14.0/16.0 Dimension (Height) <mm> Dimension (Width) <mm> 1280 1600 Dimension (Depth) <mm> Net weight <kg> Fan Airflow rate (Low-Middle2-Middle1-High) <m /min> 10-11-12-13 14-15-16-18 21-24-26-28...
  • Page 16 ..........129 ............130 ............137 ..............134 ..............138 ................137 ...........140 ..........142...
  • Page 17 PKFY-P·VBM-E PKFY-P·VHM-E PCFY-P·VKM-E PMFY-P·VBM-E PFFY-P·VKM-E2 ”. PMFY-P·VBM-E PKFY-P·VBM-E PKFY-P·VHM-E PCFY-P·VKM-E PFFY-P·VKM-E2...
  • Page 18 Main Main menu Vane·Louver·Vent. (Lossnay) High power Room Timer Cool Set temp. Auto Weekly timer OU silent mode Main display: Cursor Page Mode Temp.
  • Page 19 2 3 4 5 6 Cool Set temp. Auto Room Cool Set temp. Auto Mode Temp. Mode Temp.
  • Page 21 19 – 30 ºC 17 – 28 ºC 19 – 28 ºC Room Cool Set temp. Auto Mode Temp. Cool Auto Heat 28.5 Room Room Cool Set temp. Auto Cool Set temp. Auto 28.5 Mode Temp. Mode Temp.
  • Page 22 MODEL SELECT MODEL SELECT MODEL SELECT ON/OFF TEMP AUTO STOP MODE VANE AUTO START CHECK LOUVER TEST RUN RESET CLOCK Main Main menu Vane·Louver·Vent. (Lossnay) High power Timer Weekly timer OU silent mode Room Main display: Cool Set temp. Auto Cursor Page Mode...
  • Page 23 Main Main menu Vane·Louver·Vent. (Lossnay) Swing High power Timer Weekly timer OU silent mode Main display: Cursor Page Vane Vent. Louver Auto Auto Step 1 Step 2 Step 3 Step 4 Step 5 Swing Swing OU silent mode Tue Wed Thu Fri Sat Sun Start Stop Silent...
  • Page 24 COOL HEAT 24°C 24°C...
  • Page 25 Room Room Cool Set temp. Auto Cool Set temp. Auto Mode Temp. Mode Temp. Main Main menu Restriction Energy saving Night setback Filter information Error information Main display: Cursor Page Filter information Please clean the filter. Press Reset button after filter cleaning.
  • Page 26 PCFY-P·VKM-E PFFY-P·VKM-E2 PMFY-P·VBM-E PKFY-P·VBM-E PKFY-P·VHM-E...
  • Page 27 ”.
  • Page 28 — —...
  • Page 29 PCFY-P·VKM-E P100 P125 ~/N 220-230-240/50, 220/60 4,5/5,0 7,1/8,0 11,2/12,5 14,0/16,0 1280 1600 10-11-12-13 14-15-16-18 21-24-26-28 21-24-27-31 29-32-34-36 31-33-35-37 36-39-41-43 36-39-42-44 PKFY-P·VBM-E PKFY-P·VHM-E ~/N 220-230-240/50, 220/60 1,7/1,9 2,2/2,5 2,8/3,2 3,6/4,0 4,5/5,0 5,6/6,3 4,9-5,0-5,2-5,3 4,9-5,2-5,6-5,9 9-10-11 9-10,5-11,5 9-10,5-12 29-31-32-33 29-31-34-36 34-37-41 34-38-41 34-39-43 PMFY-P·VBM-E ~/N 220-230-240/50, 220/60...
  • Page 30 única responsabilidade que os aparelhos de ar condicionado e bombas de calor abaixo descritos para uso residencial, comercial e de indústria ligeira: erklærer hermed under eneansvar, at de herunder beskrevne airconditionanlæg og varmepumper til brug i privat boligbyggeri, erhvervsområder og inden for let industri: MITSUBISHI ELECTRIC, PKFY-P15VBM-E*, PKFY-P20VBM-E*, PKFY-P25VBM-E* Note: Its serial number is on the nameplate of the product.
  • Page 31 <ENGLISH> <PORTUGUÊS> English is original. The other languages versions are translation of the original. O idioma original é o inglês. As versões em outros idiomas são traduções do idio- ma original. CAUTION CUIDADO EN378-1. in burns or frostbite. tubagem pode resultar em queimaduras ou úlceras causadas pelo frio. o seu funcionamento.
  • Page 32 This product is designed and intended for use in the residential, commercial and light-industrial environment. Importer: Mitsubishi Electric Europe B.V. Capronilaan 46, 1119 NS, Schiphol Rijk, The Netherlands French Branch 25, Boulevard des Bouvets, 92741 Nanterre Cedex, France German Branch...

This manual is also suitable for:

Pkfy-pvhm-ePmfy-pvbm-ePffy-pvkm-e2Pcfy-pvkm-e

Table of Contents