Wiring the Inter-Unit Connections
1) Remove the 4 screws anchoring the electrical box
cover, and open the cover. (Fig. 6)
2) Install the inter-unit wiring onto the terminal board
located inside the electrical box. (Fig. 7)
Be sure to comply with the wiring diagram.
3) Anchor the inter-unit wiring with the clamp. (Fig. 8)
CAUTION
Mounting the Receiver
1) Connect the receiver connector to the socket
located outside the electrical box. (Fig. 9)

7-3. Increasing the Fan Speed

If external static pressure is too great (due to long
extension of ducts, for example), the air flow volume
may drop too low at each air outlet. This problem may
be solved by increasing the fan speed shifting the static
pressure switch from L to H. (Fig. 10)