hit counter script

Lenovo HX3510-G Installation And Service Manual page 379

Converged hx series server
Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0494
User Response
1. Reduce the ambient temperature.
2. Ensure the air baffle is installed correctly.
3. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
80010901-1403ffff : Numeric sensor [NumericSensorElementName] going high (upper critical)
has asserted. (DIMM AB VR Temp)
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109011403ffff or 0x800109011403ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Reduce the ambient temperature.
2. Ensure the air baffle is installed correctly.
3. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
80010901-1404ffff : Numeric sensor [NumericSensorElementName] going high (upper critical)
has asserted. (DIMM CD VR Temp)
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109011404ffff or 0x800109011404ffff
Appendix A. Integrated management module II (IMM2) error messages