Page 4
Regulatory information European Union Declaration of Conformity Hereby, “NEC Unified Solutions”, declares that this “AP400” is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. http://www.nec-unified.com/doc PRODUCT DISPOSAL INFORMATION (EN) For countries in the European Union...
1.11 INSTALLATION PROCEDURES ............... 16 1.12 UNPACKING ..................... 17 ADJUSTING THE ANTENNA POSITION ..............18 MOUNTING THE G.729 DAUGHTERBOARD ............23 MOUNTING THE AP400 AGAINST A WALL/CEILING ..........26 LEDs .......................... 30 LED Status ......................30 LED Colours ...................... 31 SPECIFICATIONS ......................
Page 11
PREFACE This manual is applicable for the AP400, DECT Transceiver. Please note that some product models or features described in this manual may not be available in all world regions.” No legal rights can be obtained from information in this manual.
AP400 GENERAL GENERAL This installation Manual is valid for installing a DECT transceiver (AP400) to a wall in horizontal or vertical position. The AP400 is designed for indoor use. When installing an AP400 outdoors, please use the dedicated Outdoor Cabinet and appropriate outdoor...
The Outdoor Cabinet should not be exposed to sunlight! CABLE SPECIFICATIONS FOR AP400 Types The cabling to the AP400(E) should be “Category 5” or “Category 6” Ethernet cabling. The interface is defined as an SELV interface according EN60950-1. For this reason the safety restriction as given in the next chapter should be respected: AP400 –...
CABLING SAFETY REGULATIONs Please read the following notes carefully: Note: When you are going to install an AP400(E) outdoors, it should always be installed in an Outdoor Box. Note: The cabling and/or the AP400(E) may never be exposed to over-voltages (e.g.
G.729 DAUGHTER BOARD The AP400 does support the G.729 codec, but only if the G.729 Daughter Board is installed. If the G.729 Daughter Board is not installed, the AP400 supports only G.711u law or G.711a law. Installation of the Daughter Board is described in chapter 3.
When the AP400 is mounted horizontally, the antenna position must be changed (see chapter 2). Figure 2. AP400 mounted horizontally 1.11 INSTALLATION PROCEDURES The installation of an Outdoor Cabinet comprises the installation of: Adjusting the Antenna position (if necessary). Mounting the G.729 Daughter Board (if applicable) Mounting the AP400 against the wall.
Check the AP400 for any damage. Continue with one of the following Chapters: When you mount the AP400 vertically, the antenna position will normally be OK, and when you do not need to install the G.729 Daughter Board, continue with Chapter 4 MOUNTING THE AP400 AGAINST A WALL.
ADJUSTING THE ANTENNA POSITION This chapter is not applicable for the AP400E. Note: You only need to change the antenna position when you mount the AP400 horizontally! In all other cases you don’t need to change the antenna position. Figure 3. AP400 mounted horizontally PROCEDURE: “Adjusting the Antenna position”.
Page 20
Open the cabinet CAREFULLY! Make sure that you shift the cover of the antenna’s carefully from the antenna’s. Take the antenna cover from the AP400 cover. To put the antennas in vertical position, bend them carefully as shown in Figure 5.
Page 21
Figure 5. Bend Antennas carefully into vertical position. After the antennas are put in the vertical position, close the AP400 cabinet again. In other words, put the AP400 cover back into position and secure the screws at the rear side of the cabinet. See Figure 6. Antennas locked into Cover.
Page 22
Make sure that the antennas are properly locked into the locks in the AP400 cover. Figure 7. Detail of Antenna in lock. Move the antenna cover carefully over the antennas in the vertical position and make sure that the antennas do not bend. When the antenna cover is in its position, push it further into its position in the AP400 cabinet to fix it.
Note: Mind the light conductor for the LEDs. It can drop off! LED Light conductor Figure 9. Light conductor for LEDs Now you should have the AP400 PWB and the G.729 Daughter Board as separate items. Remove the protection foil from the sticky part on the G.729 Daughter Board.
MOUNTING THE AP400 AGAINST A WALL/CEILING PROCEDURE: “Procedure for mounting the AP400 to the wall”. Actions Remove the mounting plate from the AP400 cabinet. Push clip up, to take mounting plate off. Figure 12. How to take the mounting plate off.
Page 30
Push the cabinet onto the mounting plate. Note: When pushing the AP400 on to the mounting plate, make sure that you hear/feel a distinct click. This indicates that the AP400 is firmly mounted to the mounting plate. Figure 15. AP400 mounted against the wall.
LEDs LED Status The AP400 is equipped with two LEDs. Top LED – Yellow This LED represents the status of the AP400. LED Status (Top LED, Yellow) Meaning No power 0,5 seconds On - 0,5 seconds Loading software/firmware Short flash every 0,25 seconds...
Green flashing Network status display and showing network activity AP400 operational Table 2. Lower LED status on the AP400. LED Colours The colour of the top LED might be different depending on the operational mode. The following operational modes are distinguished: Normal (single band) mode In the normal single band mode, the top LED will be Yellow.
In Outdoor Box = IP66 Relative Humidity ......... : 5 . . . 95 % PoE Specifications: Voltage at AP400 via PoE ......: 36 ..57 V. DC PoE Class ............ : Class 2 Power Consumption ........: 6 Watt maximum Note: PoE source must comply with clause 2.5 (Limited Power Source) per EN 60950-1...