Page 3
Taiwan product service ... . The Lenovo Documentation CD ..1 Appendix B. Notices..23 Hardware and software requirements .
Page 4
Safety Before installing this product, read the Safety Information. Antes de instalar este produto, leia as Informações de Segurança. Læs sikkerhedsforskrifterne, før du installerer dette produkt. Lees voordat u dit product installeert eerst de veiligheidsvoorschriften. Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information. Avant d'installer ce produit, lisez les consignes de sécurité.
Page 5
Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten. Each caution and danger statement in this document is labeled with a number. This number is used to cross reference an English-language caution or danger statement with translated versions of the caution or danger statement in the Safety Information document.
Page 6
Statement 1 DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: • Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. • Connect all power cords to a properly wired and grounded electrical outlet. •...
Page 7
DANGER Overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions. To avoid these hazards, ensure that your system electrical requirements do not exceed branch circuit protection requirements. Refer to the information that is provided with your device for electrical specifications.
Chapter 1. Introduction The Lenovo RackSwitch G7000 Redundant Power Supply (RPS) is a 1U redundant power supply. Up to four RackSwitches can be connected to a single dedicated power source. Note: The power supply comes with an attached power cord.
The G7000 redundant power supply is a 1U rack-mountable DC power supply that supports up to four RackSwitches. The following illustrations show the front panel and rear panel of the power supply. Figure 1. G7000 Front view Figure 2. G7000 front panel detail Figure 3. G7000 rear view Lenovo RackSwitch G7000 Redundant Power Supply Installation Guide...
Hardware options The following list provides an overview of the redundant power supply hardware. • Redundant power supply • Mounting hardware Status LEDs The following illustration shows the power supply status LEDs. The redundant power supply LEDs are described in the following table. Table 1.
Altitude, storage 12,190 m (39,993 feet) Acoustic noise Less than 65 dB Heat dissipation 1239 BTU/hour Power specifications The power specifications for the redundant power supply are listed in the following table. Lenovo RackSwitch G7000 Redundant Power Supply Installation Guide...
Page 13
Table 5. AC power specifications Specification Measurement Number of power supplies AC-input frequency (universal) 50 - 60 Hz AC-input voltage (universal) 100 - 240 VAC AC inrush current 102.4 A (RMS) @ 120 VAC/60 Hz 145 A (RMS) @ 230 VAC/50 Hz AC-input current (maximum) 3.438 A (RMS) @ 120 VAC/60 Hz 1.760 A (RMS) @ 230 V/...
Page 14
Lenovo RackSwitch G7000 Redundant Power Supply Installation Guide...
This chapter describes how to install and remove the redundant power supply in the following racks: • Installing and removing the redundant power supply in a standard equipment rack • Installing and removing the redundant power supply in a Lenovo System x or IBM Power rack Before installing the redundant power supply Locate and record the important product information about the G7000 unit in the following table.
• Make sure that twisted-pair cable is routed away from power lines, fluorescent lighting fixtures and other sources of electrical interference. Preventing electric shock This product does not contain any user-serviceable parts. Do not remove the cover of this device. Lenovo RackSwitch G7000 Redundant Power Supply Installation Guide...
DANGER When working on or around the system, observe the following precautions: Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: • Connect power to this unit only with the provided power cord. Do not use the provided power cord for any other product.
This section describes how to install and remove the redundant power supply in a standard 19-inch equipment rack. For information about mounting the redundant power supply in Lenovo System x racks, see Installing and removing the redundant power supply in a Lenovo System x or IBM Power rack.
Attention: For earthquake stability, mount the switch in a 4-post rack. Installing the redundant power supply To install the G7000 redundant power supply in a standard equipment rack, complete the following steps: Step 1. Locate and record the product information to register your product and set aside. See Before installing the redundant power supply.
Step 3. Slide the redundant power supply out of the rack. Step 4. Loosen and remove the M4 screws attaching the mounting bracket on each side of the redundant power supply. Lenovo RackSwitch G7000 Redundant Power Supply Installation Guide...
Installing and removing the redundant power supply in a Lenovo System x or IBM Power rack This section describes how to install and remove the redundant power supply in a Lenovo System x 4-post rack. For information about mounting the redundant power supply in other rack types, see Installing and removing the redundant power supply in a standard equipment rack.
Installing the redundant power supply To install the redundant power supply in a Lenovo System x or IBM Power rack, complete the following steps: 1. Locate and record the product information to configure and register your product and set aside. See Before installing the redundant power supply.
Page 23
5. Slide the rear mounting brackets into the slots available on the front mounting brackets. SEE STEP 5 6. Use M6 washers, screws, and clip nuts to attach the filler plate to the rear mounting brackets. Torque the screws to approximately 3.5 Nm (30 inch-pounds). Chapter 2 Installing and removing the redundant power supply...
To remove the redundant power supply from a System x rack, complete the following steps: 1. Disconnect all external cables. 2. Loosen and remove M3 screws that secure the rear brackets to the front brackets. Lenovo RackSwitch G7000 Redundant Power Supply Installation Guide...
Page 25
3. Loosen and remove M6 washers, screws, and clip nuts that attach the filler plate to the rear mounting brackets. 4. Slide the rear mounting brackets out of the slots available on the front mounting brackets. Chapter 2 Installing and removing the redundant power supply...
Page 26
5. Loosen and remove the M6 screws, washers, and clip nuts are used to connect the front mounting brackets to the front and rear posts in the rack. 6. Slide the redundant power supply out of the rack. Lenovo RackSwitch G7000 Redundant Power Supply Installation Guide...
Page 27
7. Loosen and remove the M4 screws that attach the front mounting brackets to each side of the redundant power supply. 8. Record the product MTM number and serial number to use for the replacement redundant power supply, see Before installing the redundant power supply. Chapter 2 Installing and removing the redundant power supply...
Page 28
Lenovo RackSwitch G7000 Redundant Power Supply Installation Guide...
Before you call, make sure that you have taken these steps to try to solve the problem yourself. If you believe that you require warranty service for your Lenovo product, the service technicians will be able to assist you more efficiently if you prepare before you call.
If you suspect a software problem, see the documentation for the operating system or program. Using the documentation Information about your Lenovo system and preinstalled software, if any, or optional device is available in the product documentation. That documentation can include printed documents, online documents, readme files, and help files.
Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead.
(TBW). A device that has exceeded this limit might fail to respond to system-generated commands or might be incapable of being written to. Lenovo is not responsible for replacement of a device that has exceeded its maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the device.
If Lenovo determines that the levels of particulates or gases in your environment have caused damage to the device, Lenovo may condition provision of repair or replacement of devices or parts on implementation of appropriate remedial measures to mitigate such environmental contamination.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Lenovo is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user's authority to operate the equipment.
Klasse A. Dieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG das EG-Konformitätszeichen - CE - zu führen. Verantwortlich für die Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo (Deutschland) GmbH, Gropiusplatz 10, D-70563 Stuttgart. Informationen in Hinsicht EMVG Paragraf 4 Abs. (1) 4:Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A.
This is for any areas other than home. Russia Electromagnetic Interference (EMI) Class A statement People's Republic of China Class A electronic emission statement Taiwan Class A compliance statement Lenovo RackSwitch G7000 Redundant Power Supply Installation Guide...
Page 40
United States electronic emission Class A notice physical United States FCC Class A notice power Lenovo RackSwitch G7000 Redundant Power Supply Installation Guide...