Code
E842
Error in unlocking of external heat roller
0009 With the fixing roller in stop state, hardware has detected that the
Error in locking of external heat roller
0001 The HP sensor does not go on within 5 sec after the start of a HP
0011 The HP sensor is logically displaced at the time of executing
0101 At the time of finishing the operation, it is not positioned in a
1001 Between HoldOn at starting operation and MtrOn (50msec), the
Error in locking of fixing belt
0002 The belt HP sensor does not go on within 5 sec after the start of a
0012 The HP sensor is logically displaced at the time of executing
0102 At the time of finishing the operation, it is not positioned in a
1002 Between HoldOn at starting operation and MtrOn (50msec), the
Error in locking of web
0003 The web HP sensor does not go on within 5 sec after the start of a
0013 The HP sensor is logically displaced at the time of executing
0103 At the time of finishing the operation, it is not positioned in a
1003 Between HoldOn at starting operation and MtrOn (50msec), the
E905
Error in air assist fan of paper deck
0001 The swing of the air assist fan does not return after 5 sec (During
E906
Error in heater of paper deck
0001 <High temperature error> Detects 120 deg C or more for 1 sec
0002 <Low temperature error> after heater is turned on, the heater is not
15.2.2 E602 (HDD/Encryption board error) detail
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
<E602-XXYY>
In case of XX=[00]
Cause (Detection Description)
external heat roller had remained in contact with the fixing roller
for 300 msec or more continuously.
search.
operation.
specified position.
theory of sensor has changed
HP search.
operation.
specified position.
theory of sensor has changed
HP search.
operation.
specified position.
theory of sensor has changed
the swing operation with the fan rotating, positioning sensor
logically does not change for 5 sec or more).
continuously (hard port monitoring)
ready. With the heater for air-assist (separation by air) is activated,
the temperature is not high enough for controlled temperature
despite the passage of the specified time (hard port monitoring)
Remedy
Check the detached/attached motor of the external heat roller.
Check the HP sensor of the external heat roller.
Check the detached/attached motor of the external heat roller.
Check the HP sensor of the external heat roller.
Check the detached/attached motor of the external heat roller.
Check the HP sensor of the external heat roller.
Check the detached/attached motor of the external heat roller.
Check the HP sensor of the external heat roller.
Check the detached/attached motor of the external heat roller.
Check the HP sensor of the external heat roller.
Check the detached/attached motor of the fixing belt. Check the
HP sensor of the fixing belt. Check the attached sensor of the
fixing belt.
Check the detached/attached motor of the fixing belt. Check the
HP sensor of the fixing belt. Check the attached sensor of the
fixing belt.
Check the detached/attached motor of the fixing belt. Check the
HP sensor of the fixing belt. Check the attached sensor of the
fixing belt.
Check the detached/attached motor of the fixing belt. Check the
HP sensor of the fixing belt. Check the attached sensor of the
fixing belt.
Check the detached/attached motor of the cleaning web.
Check the detached/attached motor of the cleaning web.
Check the detached/attached motor of the cleaning web.
Check the detached/attached motor of the cleaning web.
Check the connector of the air assist fan. Replace the air assist fan.
Replace the heater of the paper deck. Replace the deck driver.
Check the power supply of the paper deck. Check the supplying
path. Replace the heater of the paper deck. Replace the deck
driver.
Chapter 15
0019-4907