hit counter script
Download Print this page
Sanyo 26THW72R Specifications

Sanyo 26THW72R Specifications

Ceiling suspended heat pump
Hide thumbs Also See for 26THW72R:

Advertisement

Split System Submittal Data
System: 26THW72R
Ceiling Suspended Heat Pump
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
(A)
Fuse Size, Max.
(A)
Compressor
No. used
R.L. Amps - L.R.
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
(RPM)
No. Motors
(High)
CFM
(A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
(RPM, High)
No. Poles
No. Motors
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
(in.)
(in.)
Drain Connection Size
Indoor/Outdoor: THW2672R/CH2672R
General Data (at 230V)
230/208/1/60
15-30 Indoor-Outdoor
15-30 Indoor-Outdoor
DC Rotary Inverter
(A)
12.9-17.5
Propeller
18-7/64-1
DC Motor
8 - 800
(W)
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffeled
1-15.9
(in.)
Centrifugal
5-1/8 - 4
3 & Auto
4 - 1179
(W)
550/490/460
(A)
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riffeled
3 - 14.9
1-1/4"
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
1 - 90
1765
Outdoor Unit
13.8
Weight
Net
Shipping
7.26
3/8"
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
Sensible Capacity
1 - 31
Latent Capacity
SEER
Dehumidification
39
0.5
Amps
Power Inputs
Outdoor Sound Rating
Heating
Total Capacity
1.81
HSPF
9/32"
Electric Expansion Valve
50 (outdoor lower), 100 (outdoor higher)
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
7-17/16 x 51-3/16 x 26-3/8
(Crated)
9-7/16 x 54-19/32 x 31-1/16
(Uncrated)
30-23/32 x 37 x 13-3/8
(Crated)
34-31/32 x 39-31/32 x 16-3/32
Indoor
(lbs.)
64
(lbs.)
75
Indoor
(cu.ft.)
8.9
(BTU/H)
24,400 (9,500-24,400)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
(W)
(dB-A)
(BTU/H) 30,800 (8,000-30,800)
R410A
4.19
Flare
165
3/8"
5/8"
H x W x D
Outdoor
128
148
Outdoor
13.0
14,330
10,070
14.5
7.7
15.6/17.3
2,880/2,880
49
10.3

Advertisement

loading

Summary of Contents for Sanyo 26THW72R

  • Page 1 Split System Submittal Data System: 26THW72R Indoor/Outdoor: THW2672R/CH2672R Ceiling Suspended Heat Pump Job Name: Location: Engineer: Submitted to: Submitted by: Reference: General Data (at 230V) Power V/PH/Hz Circuit Ampacity Fuse Size, Max. Compressor No. used R.L. Amps - L.R. Outdoor Unit Fan type Dia.
  • Page 2 Power Failure Automatic Restart Dimensional Data for 26TH72R Heating/Cooling Automatic Changeover Indoor unit : TH2672R Self-Diagnosis Air Filter Sanyo Commercial Solutions A Division of SANYO North America 1300 Michael Drive Wood Dale, IL 60191 USA www.sanyohvac.com Options Refrigerant Line Set 16.4/18.1 Fresh Air Intake 16.4/18.1...

This manual is also suitable for:

Thw2672rCh2672r