free stats
Sealey GI2300 Instructions For Use Manual
Sealey GI2300 Instructions For Use Manual

Sealey GI2300 Instructions For Use Manual

Inverter generator 2300/3500w 230v 4-stroke engine

Advertisement

thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
electrical
refer to
shock
instructions
hazard
1. safety
WARNING! The Generator is shipped without oil. Check oil level and fill as required before use.
Warning! Ensure any Health & Safety, Government, or local authority regulations are adhered to when using this equipment.
familiarise yourself with the application and limitations, as well as the potential hazards, of the generator.
9
maintain the generator in good condition (use an authorised service agent). replace or repair damaged parts. use genuine parts only.
9
unauthorised parts may be dangerous and will invalidate the warranty.
this generator is designed and manufactured for specific applications. Do not attempt to modify the unit or use it for any application
9
for which it is not designed. if you have any questions regarding the application of the unit please contact your local sealey stockist.
Warning! Do not exceed the Wattage/Amperage capacity of the generator. Add rated wattage of all devices intended for
connection at any one time, the total must not exceed rated wattage of generator (see specifications).
Warning! Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient ventilation.
Warning! if you decide to use an earth leakage circuit Breaker (also referred to as an rcd or Ground fault circuit interrupter),
it is imperative that the neutral end of the power winding is connected to the frame of the generator set and that the earth lug on the
frame is connected with a low impedance connector to the local earth via an earth spike or local protective earth conductor. this
connection should only be attempted by a qualified electrician, after first having consulted your local stockist.
Danger! this generator is designed for outdoor use only. to use the generator inside any building or enclosure, including the
generator compartment of a caravan, may result in fire or an explosion. no user performed modifications, including venting of the
exhaust and/or cooling ventilation, will eliminate the danger.
Danger! if this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken.
Before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from the
commercial electric supply. failure to do this may result in damage to the generator and may result in serious injury or fatality, due to a
back-feed of electrical energy.
Danger! the generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare wires,
terminals etc. never allow any unqualified person to operate or service the generator.
Warning! Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat in the
vicinity while handling petrol. Avoid spilling petrol onto a hot engine. comply with all laws regulating storage and handling of fuels.
Warning! risk of burns. Do not touch the exhaust system or the drive unit.
Warning! never refuel when the engine is running or when the engine is hot. Allow cool down time.
operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt
9
or corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases).
Do not tip or change the generator's position whilst it is operating.
8
remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair. Wear appropriate protective clothing.
9
Keep non-essential persons and children away from the working area.
9
Warning! never start or stop the generator while electrical loads are connected. start the engine, let it stabilise, then connect the
electrical load. to stop engine, disconnect the electrical load and let engine stabilise before switching off.
Warning! Do not use worn, bare, frayed or otherwise damaged electrical cables with the generator. electric shock may occur.
Do not use the generator for any purpose other than that for which it is designed.
8
Do not operate the generator if any parts are missing or damaged, as this may cause failure and/or personal injury.
8
Do not over-fill fuel tank. Always leave room for fuel to expand.
8
Do not operate in the rain.
8
Danger! Do not tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase the risk
of personal injury and/or equipment damage. the generator supplies the correct rated frequencies and voltage only when running at the
correct governed speed. incorrect frequency and/or voltage can damage some connected electrical loads.
operating at excessively low speeds may result in shortened engine life. over-speeding will invalidate the warranty.
Do not operate the generator when you are tired, or under the influence of alcohol, drugs or intoxicating medication.
8
Do not store generator with fuel in tank where petrol vapours might reach an open flame or spark.
8
the generator must be grounded with a good quality insulated conductor.
9
Keep vents free from dirt etc.
9
If supplying electronic equipment, or in an area where electronic equipment is being used, keep the generator a sufficient distance
9
away to prevent electrical noise from the engine.
© Jack sealey limited
instructions for
inverter generator 2300/3500W 230v
4-stroke engine
model no:
Hot surfaces
do not cover
Original Language Version
gi2300, gi3500
do not use in
switch off the engine
non ventilated
Before refuelling
area
GI2300,GI3500 Issue 2 (fig1) 19/04/18

Advertisement

Table of Contents
loading

Summary of Contents for Sealey GI2300

  • Page 1 Do not attempt to modify the unit or use it for any application for which it is not designed. if you have any questions regarding the application of the unit please contact your local sealey stockist.
  • Page 2: Specification

    Heavy-duty frame provides full protection and incorporates carry handles for portability. inverter generator suitable for running sensitive electrical equipment. Produces a clean AC current to match the load. Long running time of up to 8 hours on a full tank of fuel. Fitted with two 230V 13 Amp sockets. Increased fuel efficiency compared to standard generators. Features oil warning light, overload indicator and sight glass to monitor fuel level. 3. specification model no ........Gi2300......Gi3500 motor Power ......2.3KW......3.5KW motor type ....4-Stroke Petrol....4-Stroke Petrol output ......230V-50Hz....230V-50Hz current rating ......8.3A......15.2A continuous Power rating..2000W......3200W...
  • Page 3 Recommended engine oil SAE SJ 15W-40. fig.9 4.8.6. Engine oil capacity 0.45L. 4.9. standard atmospheric conditions Ambient temperature 25 Barometric pressure 100kPa relative humidity 30% the output of the generator will vary dependant on the deviation from the standard conditions. Original Language Version GI2300,GI3500 Issue 2 (fig1) 19/04/18 © Jack sealey limited...
  • Page 4 Original Language Version GI2300,GI3500 Issue 2 (fig1) 19/04/18 © Jack sealey limited...
  • Page 5: Maintenance

    Wash the foam element in solvent and dry it. 5.7.4. oil the foam element and squeeze out excess oil. 5.7.5. the foam element should be wet but not dripping. 5.7.6. Insert the foam element into the air filter case. 5.7.7. Install the air filter case cover in position and tighten screws. Original Language Version GI2300,GI3500 | Issue 1 fig1 19/04/18 © Jack sealey limited...
  • Page 6: Troubleshooting

    Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. sealey group, kempson Way, suffolk Business park, Bury st edmunds, suffolk. ip32 7ar 01284 757500 01284 703534 sales@sealey.co.uk...