thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: pleaSe read tHeSe inStructionS carefully. note tHe Safe operational reQuireMentS, WarningS & cautionS. uSe tHe product
correctly and WitH care for tHe purpoSe for WHicH it iS intended. failure to do So May cauSe daMage and/or perSonal inJury and Will
inValidate tHe Warranty. keep tHeSe inStructionS Safe for future uSe.
Wear eye
refer to the
protection
instruction
manual
1. Safety
Warning! ensure that Health and safety, local authority and general workshop practice regulations are adhered to when using this
air conditioning leak detection kit.
Warning! the leak detection fluid is an irritant if it contacts skin or eyes. A safety data sheet covering the leak detection fluid
Vs60012 and Vs60033 is obtainable via your local sealey dealer.
do not use this kit if damaged, leaking at connections or hose and if you are not wearing the protection shown above. A full range of
safety PPe is available from your local sealey dealer.
Warning! do not look into the uV lamp, even if wearing the uV goggles.
do not point the uV lamp at yourself, other people or animals.
maintain the items in the kit in good and clean condition for best and safest performance.
Account for all kit items during use and do not place any on or near the engine.
on completion of the work, replace all the kit items back in the carry case and store in a cool, dry, childproof area.
Warning! the warnings, cautions and instructions in this manual cannot cover all possible conditions and situations that
may occur. it must be understood by the operator that common sense and caution are factors which cannot be built into
this product, but must be applied by the operator.
IMPORTANT: These instructions are provided as a guide only. Always refer to the vehicle manufacturer's service instructions, or a proprietary
manual to establish the current procedure and data.
2. introduction
Find leaking hoses and joints in vehicle r134A air conditioning systems fast. supplied with rugged 12V ultraviolet lamp and dye injector system
for use in conjunction with any air conditioning recharge/recycle station. Includes ten single doses of fluorescing dye and UV enhancing
spectacles for use in normal workshop lighting conditions. supplied with hose adaptors, comprehensive operating instructions and carry-case.
3. Specification
Model no: . . . . . . . . . . . . . . . . . VS600.V2
temperature:. . . . . . . . . . . . . .10°c to 45°c
Humidity:. . . . . . . . . . . . . . . . . . . 20 to 90%
lamp type:. . . . . . . . . . . dichroic uV lamp
Power rating:. . . . . . . . . . . . . . . . . . . 50W
Power supply: . . . . . . . . . . . . . . . . 12V dc
supply cable length: . . . . . . . . . . .3metres
4. contentS
Item
descrIPtIon
1
12V uV lamp/cable/battery clips
2
reservoir/injector valve
3
rotating connector 6/4
4
rotating connector 4/6
5
uV dye (x10)
6
uV Goggles