1.
INTRODUCTION
Digital display for the cross slide and the compound tool rest to replace the standard graduated scales. These LCD units improve accuracy, save
reading time and minimise errors. Imperial or Metric readings may be selected and the reading can be zeroed at any point. Three decimal place
(Metric) and four decimal place (Imperial) displays with an accuracy of ± 0.025mm/0.001"".
2.
CONTENTS
1. Cross slide feed screw
2. Compound rest feed screw
3. Screws and spacers
4. Cross slide screw retainer
5. Cross slide feed nut
6. Compound rest screw retainer
7. Compound rest bottom
8. Digital displays
3.
INSTALLATION 1
Installing the Compound Rest digital display.
a
fig 1
3.1 Loosen the compound rest gibs
(fig 1a) and crank the compound rest
feed handle anticlockwise to remove the
top of the compound rest from the
compound rest bottom.
fig 4
3.4 Move the protractor (fig 4a) to the
new compound rest bottom (fig 4b) and
slide the compound rest top (fig 4c) a
short way onto the new compound rest
bottom, being sure to leave the two large
screw holes uncovered.
© Jack Sealey Limited
fig 2
3.2 Undo the handle screw of the graduated
scale (fig 2a) and remove the spring clip
and scale (fig 2b). Remove the compound
rest screw retainer (fig 2c) (retaining the
fixing screws for future use) and remove
the compound rest feed screw.
b
a
fig 5
c
3.5 Screw the compound rest back onto
the cross slide using the two large hex
screws. Adjust the gib screws so that the
compound rest may be moved by hand
but with some resistance.
Original Language Version
INSTRUCTIONS FOR:
DIGITAL FEED DISPLAY FOR SM3002
SM3002DFD
MODEL:
7
4
fig 3
c b a
3.3 Remove the two large hex screws
(fig 3a) (retaining them for future use).
Remove the compound rest
bottom (fig 3b) from the cross slide.
fig 6
3.6 Screw the new compound rest feed
screw into the compound rest bottom.
8
1
2
6
5
b
a
SM3002DFD
Issue: Issue: 2(L) - 12/05/16
3

Advertisement

loading

Summary of Contents for Sealey SM3002DFD

  • Page 1 SM3002DFD MODEL: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
  • Page 2 12a) by turning the cross slide feed handle (fig 13a), the spacer washer nut. handle clockwise. and the dial (fig 13b). Original Language Version © Jack Sealey Limited SM3002DFD Issue: Issue: 2(L) - 12/05/16...
  • Page 3 Now install the screws (taken from the original nut) that retain the feed nut. Original Language Version © Jack Sealey Limited SM3002DFD Issue: Issue: 2(L) - 12/05/16...
  • Page 4 When you are finished working on the lathe, turn both displays off by pressing the ON/OFF button on each one. MAINTENANCE The SM3002DFD requires little by way of maintenance. Keep the displays clean by occasionally wiping with a moist cloth - DO NOT use solvents or abrasives.