hit counter script

Removing And Installing Ac Power Supplies - Cisco MDS 9396S Installing

Hide thumbs Also See for MDS 9396S:
Table of Contents

Advertisement

Removing and Installing AC Power Supplies

Note
The Cisco MDS 9396S Switch is only supported for continuous operation with both power supplies and both
fan modules installed, and with all fans working.
With two power supplies installed, if one power supply fails, the system can continue to function normally
on a single healthy power supply. However, the failed power supply should be replaced as soon as possible
to provide redundancy. The fan modules are required to ensure proper cooling of the switches.
Figure 4: Rear View of the Cisco MDS 9396S Switch
Removing and Installing AC Power Supplies
This section provides instructions for removing and installing the AC power supplies for the Cisco MDS
9396S switch.
Removing Power Supplies
To remove an AC power supply, follow these steps:
Step 1
Turn the power switch to the off (0) position on the power supply that you are removing.
Step 2
Disconnect the power cord from the power source.
Step 3
Loosen the captive screw.
Step 4
Grasp the power supply handle and slide the power supply out of the switch.
Installing Power Supplies
To install an AC power supply, follow these steps:
Installing the Cisco MDS 9396S Switch