hit counter script
Hide thumbs Also See for iR5000:
Table of Contents

Advertisement

7) Cut off the excess of the charging wire
with nippers.
8) Pick the end of the charging wire ten-
sion spring with tweezers, and hook it
on the charging power supply electrode.
In the case of the pre-transfer charging
assembly, hook the spring on the pin at
the front.
Make sure of the following:
• The charging wire must not
be bent or twisted.
• The charging wire must be
fitted in the V-groove of the
charging wire positioner.
9) Attach a cushoin in front of the charg-
ing wire. (This does not apply to the
primary charging assembly.)
10) Mount the shielding plate (left, right).
For other charging assemblies,
mount the two lids.
11) Mount the wire cleaner. At this time,
pay attention to make sure that the wire
cleaner is oriented correctly.
12) Wipe the charging wire with lint-free
paper moistened with alcohol.
CHAPTER 2 STANDARDS AND ADJUSTMENTS
Correct
Grid side
Correct
F02-203-07
Wrong
Wrong
F02-203-08
2-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir6000