Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions
and maintained properly, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to Instruction
Wear Protective
Manual
Gloves
1. SAFETY
WARNING! Ensure Health & Safety, local authority, general workshop practice regulations are adhered to when using
this equipment.
WARNING! Installation site must be equipped with suitable fire extinguishers (water must not be used) and escape routes.
WARNING! Disconnect the air supply from the tank before changing accessories, servicing or performing any maintenance.
Maintain the tank in good condition (use an authorised service agent).
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
Locate the tank in a suitable work area. Ensure the tank stands on a firm, level surface. Keep area clean and tidy and free from unrelated
materials. Ensure the area is well ventilated and has adequate lighting.
WARNING! Ensure specified air pressure is maintained and not exceeded.
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use, and ensure that all connections are
secure.
WARNING! This tank is recommended for use only with degreasing solvents suitable for air operated tanks.
Ensure you follow makers instructions for solvent use.
Ensure solvent flash point is above 140°F. We recommend you use Sealey solvent - contact your local dealer for details.
Keep the tank clean. Remove and clean the suction filter regularly for best performance.
WARNING! DO NOT SMOKE and keep sources of ignition, such as heaters, lamps, etc., away from the unit, together with
flammable or combustible materials, as there is an explosion risk.
DO NOT modify or jam the parts washer lid open, as this will make the fusible fire link inoperative which is dangerous practice and will
invalidate the warranty and your insurance.
When cleaning parts ensure that nothing in the tank, including any parts basket, is in a position that would prevent the lid from
closing fully if and when the fusible link activates.
WARNING! Wear approved safety eye protection, mask and gloves. If solvent gets on skin or in eyes wash thoroughly with water
and take any other action as required by the solvent instructions.
Remove ill fitting clothing, ties, watches, rings and other loose jewellery, contain long hair and wear appropriate protective clothing.
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
Keep non-essential persons away from the working area.
In case of fire in tank, do not attempt to move unit or remove parts from tank. The lid has a fusible link and will close automatically,
extinguishing the fire.
Avoid accidental starting of the washer by ensuring the unit is disconnected from the air supply when not in use.
DO NOT use the tank for any purpose other than for which it is designed.
DO NOT operate the tank if any parts are missing or damaged as this may cause failure and/or personal injury.
DO NOT over-fill the tank.
DO NOT use air line to blow dry components in tank. Only use air gun supplied. DO NOT direct air gun at yourself or others.
DO NOT leave the parts washer operating unattended.
When cleaning is complete, ensure all controls are in the 'off' position and that the air supply is disconnected.
WARNING! It is operator's responsibility to ensure that there is no uncontrolled discharge of any fluids used with this unit and
that appropriate arrangements have been made for correct disposal of waste in accordance with government / local authority
regulations.
2. INTRODUCTION
The heavy duty steel tank is made in one piece and is fitted with a fully sealed, air operated, magnetic drive pump unit. The tank is suitable for
cleaning large engine components. Included is an air blow gun for fast drying of workpiece. The lid of tank is fitted with fusible link hinge
which automatically snaps lid shut in the event of a fire. Supplied with removable shelf and parts basket.
3. SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . SM221 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SM223
Minimum Working Capacity . . . . . . . . . . . 45ltr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55ltr
Maximum Working Capacity: . . . . . . . . . . 55ltr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85ltr
Pump Output: . . . . . . . . . . . . . . . . . . 300ltr/hr . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300ltr/hr
Operating Pressure: . . . . . . . . . . . . . . . 65-125psi. . . . . . . . . . . . . . . . . . . . . . . . . . 65-125psi
Air Consumption: . . . . . . . . . . . . . . . . 8-10cfm . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10cfm
Tank Width x Depth x Height: . . . . . . . . . . 890 x 510 x 265mm . . . . . . . . 1070 x 510 x 265mm
Overall Height: . . . . . . . . . . . . . . . . . . 890mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 890mm
Air Inlet: . . . . . . . . . . . . . . . . . . . . . ¼"BSP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼"BSP
Weight: . . . . . . . . . . . . . . . . . . . . . . 35kg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42kg
© Jack Sealey Limited
INSTRUCTIONS FOR:
AIR OPERATED PARTS CLEANING TANK
SM221, SM223
MODEL NO'S:
Wear Eye
Wear a Mask
Protection
Original Language Version
Wear Protective
Clothing
SM221, SM223
Issue: 6 (L) - 07/01/16

Advertisement

loading

Summary of Contents for Sealey SM221

  • Page 1 Model No: ....SM221 ....
  • Page 2 Check the air regulator valve (fig 3.1) is off, and air inlet (fig.3.2) is disconnected from the air supply. 6.2. Fill the tank to appropriate capacity (See specifications) with Sealey solvent, or a general purpose degreaser (contact your local dealer for supply). DO NOT use any other type of solvent.
  • Page 3 Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500. NOTE: It is our policy to improve products continually and as such we reserve the right to alter data, specifications and component parts without prior notice.