free stats
Download Print this page
Sealey D12512V Instructions
Sealey D12512V Instructions

Sealey D12512V Instructions

Portable diesel tank 12v 125ltr, 220ltr

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions
and maintained properly, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear Protective
Instruction Manual
Gloves
1. SAFETY
 WARNING: this tank must ONLY be used for diesel fuel.
 Place the tank on a flat surface before filling.
 Secure the tank to strong points with ratchet straps before transporting in or on a vehicle.
 Maintain the pump in good condition (use an authorised service agent).
 Replace or repair damaged parts. Use recommended parts only. Non authorised parts may be dangerous and will invalidate the warranty.
 Keep the pump clean for best and safest performance.
 Ensure the power supply (vehicle battery) corresponds with the requirements of the pump (12V dc).
 Disconnect from battery when not in use.
 Wear protective gloves, and protective clothing when working around fuel. A full range of personal safety equipment is available from your
local Sealey dealer.
 Keep children and unauthorised persons away from the working area.
 DO NOT place the tank near any heat source.
 DO NOT start or stop the pump by connecting or disconnecting the battery clamps.
 DO NOT allow the unit to get wet.
 DO NOT operate the pump with wet hands.
 DO NOT use the pump where explosive or flammable vapours may be present.
 DO NOT tamper with the pump connections.
2. INTRODUCTION
Manufactured in Italy from HDPE for the safe transportation and dispensing of diesel fuel when supplying on site equipment. Complies with
ADR1.1.3.1.C for exemption from requirements of ADR regulations. Supplied with a 12V electric pump, 4mtr electric cable and clamps, security
valve and a 4mtr delivery hose with automatic fuel nozzle. Can be safely transported on a pick-up truck or van, with forklift points and 6 handles
for positioning. Model No's D12512V & D22012V are supplied without lockable cover - order Model No. DC125 for the optional cover. Available in
sizes 125, 220ltr. Not suitable for petrol.
3. SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D12512V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . D22012V
Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12V
Current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22A
Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140W
Tank Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . .125ltr. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220ltr
Flow Rate: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40ltr/min . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40ltr/min
Duty Cycle: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30mins on/30mins off . . . . . . . . . 30mins on/30mins off
Dimensions (L x W x H): . . . . . . . . . . . . . . . . . . .800 x 600 x 450mm . . . . . . . . . . . 800 x 600 x 650mm
Optional Lockable Cover: . . . . . . . . . . . . . . . . . .DC125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC125
fig.1
© Jack Sealey Limited
INSTRUCTIONS FOR:
PORTABLE DIESEL TANK 12V
125ltr, 220ltr
D12512V, D22012V
PART NO'S:
Key:
1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filler Cap
2 . . . . . . . . . . . . . . . . . . . . . . . . . Security Valve
3 . . . . . . . . . . . . . . . . . . . . Pump On/Off Switch
4 . . . . . . . . . . . . . . . . . . . . .Battery Clip Storage
5 . . . . . . . . Lockable Dispenser Nozzle Storage
6 . . . . . . . . . . . . . . . . .Securing Strap Locations
Original Language Version
D12512V, D22012V Issue: 1 - 23/09/15

Advertisement

loading

Summary of Contents for Sealey D12512V

  • Page 1 4mtr delivery hose with automatic fuel nozzle. Can be safely transported on a pick-up truck or van, with forklift points and 6 handles for positioning. Model No’s D12512V & D22012V are supplied without lockable cover - order Model No. DC125 for the optional cover. Available in sizes 125, 220ltr.
  • Page 2 4. OPERATION 4.1. Filling and Transport 4.1.1. Move the empty tank assembly with two persons using the hand holds moulded into the base of the unit (fig.2). DO NOT run the pump without fuel in the tank. To do so will damage the pump’s internal components and will invalidate your warranty.

This manual is also suitable for: