thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/
OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
WARNING! Ensure Health & Safety, local authority and general workshop practice regulations are adhered to when using
this equipment.
Read instructions thoroughly to ensure safe and effective use. Important! Read instructions in conjunction with
vehicle or equipment manufacturer's workshop manual.
Maintain the apparatus in good condition (use an authorised service agent). Before each use check condition of each
component. If any component is damaged, replace immediately. Use genuine parts only. Unauthorised parts may not
function correctly and will invalidate the warranty.
Use in a suitable work area. Keep area free from unrelated materials and ensure that there is adequate lighting.
WARNING! Always wear approved eye (or face) and hand protection when pressure leakage testing.
Keep children and unauthorised persons away from the working area.
DO NOT operate the leakage tester when you are tired or under the influence of alcohol, drugs or intoxicating
medication.
DO NOT clean the equipment with solvents or other harsh chemicals.
DO NOT use the leakage tester for any purpose other than that for which it is designed.
When not in use return parts to the case, and store it in a safe, dry, childproof location.
2. DESCRIPTION
designed to charge the turbo system with a low pressure of regulated workshop mains air supply; to indicate the presence of leaks
within the system. the kit includes a pressure gauge, a shut off ball valve, a pressure relief valve, a mains air male barbed quick
coupler and four pairs of system stepped adaptors for use on a wide range of hose sizes. the kit can also be used on cooling
system hoses. All items supplied in a storage case.
3. TECHNICAL SPECIFICATIONS
Part no
Adaptor sizes
VS2030.01
Ø80/85/90mm
VS2030.02
Ø65/70/75mm
VS2030.03
Ø50/55/60mm
VS2030.04
Ø35/40/45mm
4. CONTENTS
tapered stepped spigot adaptors (system inlet)
nominal bore sizes
Ø80/85/90
tapered stepped spigot adaptors (system plug)
© Jack Sealey limited
nominal bore sizes
Ø50/55/60
nominal bore sizes
Ø65/70/75
InStRUctIonS foR:
SYSTEM LEAKAGE TESTER
VS2030
ModEl n
:
o
Quick coupler
connection.
nominal bore sizes
Ø35/40/45
Original Language Version
TURBO
25psi (1.7bar)
maximum
Zero
Pressure regulator
and gauge
Vernier
(not supplied)
Pressure relief valve
at rear of regulator.
Adaptor
flexible hose
coupled to adaptor
Ball valve
(open)
VS2030
Issue: 1 - 21/11/12