free stats
Miele DA 3360 Operating And Installation Instructions

Miele DA 3360 Operating And Installation Instructions

Hide thumbs Also See for DA 3360:

Advertisement

Operating and Installation instructions
Rangehood
DA 3360
en - AU, NZ
To avoid the risk of accidents
or damage to the appliance,
it is essential to read these
instructions before it is installed
and used for the first time.
M.-Nr. 09 725 790

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 3360

  • Page 1 Operating and Installation instructions Rangehood DA 3360 en - AU, NZ To avoid the risk of accidents or damage to the appliance, it is essential to read these instructions before it is installed and used for the first time. M.-Nr. 09 725 790...
  • Page 2: Table Of Contents

    Contents Caring for the environment ......... . 3 Warning and Safety instructions .
  • Page 3: Caring For The Environment

    Caring for the environment Disposal of the packing Disposal of your old appliance material or machine The transport and protective packing Electrical and electronic appliances / has been selected from materials which machines often contain materials are environmentally friendly for disposal which, if handled or disposed of and can normally be recycled.
  • Page 4: Warning And Safety Instructions

    Any other usage is at the owner's risk. requirements. Inappropriate use Miele cannot be held liable for damage can, however, lead to personal resulting from incorrect or improper use injury and damage to property.
  • Page 5 Consult Miele authorised person in accordance a qualified electrician if in any doubt. with current national and local safety The electrical safety of this regulations.
  • Page 6 Warning and Safety instructions Do not connect the appliance to the Using at the same time as other mains electricity supply by a heating appliances that depend on multi-socket unit or an extension lead. the air from the room These do not guarantee the required safety of the appliance (e.g.
  • Page 7 Warning and Safety instructions There must be adequate ventilation of the room when the rangehood is used The overall ventilation condition at the same time as appliances burning of the dwelling must be taken into gas or other fuels. account. If in any doubt, the advice of a competent builder or, for gas, a In order to ensure safe operation, and qualified gas fitter must be sought.
  • Page 8 Warning and Safety instructions Correct use The filters should be regularly cleaned or changed as appropriate. Never use an open flame beneath Saturated filters are a fire hazard. See the rangehood. To avoid the danger of "Cleaning and care". fire, do not flambé or grill over an open flame.
  • Page 9 Safety regulations prohibit the fitting of a rangehood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from Miele or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
  • Page 10: Description Of The Appliance / Operation

    Description of the appliance / Operation...
  • Page 11 Description of the appliance / Operation a Exhaust socket C 150 mm Depending on the intensity of the cooking vapours, levels "1" to "3" are b Controls usually sufficient for normal cooking. c Grease filter When frying or cooking food with a d Pull-out deflector plate strong aroma, you may wish to select the Intensive setting "IS"...
  • Page 12: Description Of The Functions

    Charcoal filters are available to order appliance must be fitted in the exhaust from Miele or via the internet at socket in the motor unit. www.miele-shop.com (check availability). See back cover for contact details and Having a non-return flap fitted in the "Technical Data"...
  • Page 13: Cleaning And Care

    Housing To prevent immediate resoiling, the General notes Original Miele care product for stainless steel can be purchased from Miele or at The surfaces and controls are www.miele-shop.com (depending on susceptible to scratches and country). Apply sparingly with a soft abrasion.
  • Page 14: Grease Filter

    Cleaning and care Controls The controls may suffer discolouration or damage if soiling is left on them for too long. Remove soiling straight away. Observe the "General notes" on cleaning earlier in this section. Do not pull the grease filter downwards to remove while it is at Do not use stainless steel cleaning the back of the canopy.
  • Page 15 Ensure the spray arm is not obstructed. ^ Do not wash at more than 65 °C. If a Miele dishwasher is being used, ^ When putting it back, make sure that select the Sensor wash programme.
  • Page 16: Fitting And Replacing The Charcoal Filter (Optional Accessory)

    It is fitted in the canopy above the grease filter. Replacement charcoal filters can be obtained from Miele or via the internet at www.miele-shop.com (depending on country). See back cover for contact details, and "Technical data" for type and reference number.
  • Page 17: Changing A Halogen Lamp

    Cleaning and care Changing a halogen lamp ^ Pull out the deflector plate, and remove the grease filter as described earlier. ^ Switch off the fan and the lighting. Exercise caution when changing halogen lamps. They get very hot during use, and remain hot for some time after being switched off.
  • Page 18: Appliance Dimensions

    Appliance dimensions Safety distances between cooktop and rangehood (S) The minimum safety distances between the top of a cooktop and the bottom of the rangehood are as follows, unless a greater distance is specified by the manufacturer of your cooking appliance: Cooking appliance Distance...
  • Page 19: Installation

    Installation Installation accessories...
  • Page 20 Installation a 1 exhaust connection for exhaust ducting C 150 mm. b 1 reducing collar 12 screws 4 x 15 mm for exhaust ducting C125 mm. for securing the rangehood into the wall c 1 non-return flap unit. for fitting into the exhaust socket (only for air extraction mode).
  • Page 21 Installation...
  • Page 22: Positioning The Appliance In The Wall Housing Unit

    Installation Positioning the appliance in the wall housing unit To position the appliance correctly, cut the spacer strip to the required depth T, and then attach it to the back of the appliance: T= Wall unit depth K minus depth of ^ Screw the spacer strip to the bottom appliance G of the sides of the housing, flush with...
  • Page 23 Installation Do not remove the protective film between the deflector plate and the ^ Screw the brackets onto the right and appliance housing until the left inside walls of the housing unit as rangehood has been placed in the shown. The back edge of the housing unit.
  • Page 24 Installation Note for dismantling the rangehood: Undoing the screws on the left and right inside the housing releases the brackets, allowing the appliance to be removed from the unit. ^ Lift the appliance up into the housing from below, and engage in the brackets.
  • Page 25: Attaching The Lightshield

    Installation Attaching the lightshield ^ Attach the lightshield (if using). A DML 400 installation kit, available as ^ Remove the protective film between an optional accessory, is required for this. the deflector plate and the housing. Follow the installation instructions ^ Secure the front of the appliance to supplied.
  • Page 26: Adjusting The Building-In Depth

    Installation Adjusting the building-in depth Fitting the grease filter ^ Remove the protective strip around the edge of the grease filter. Fit the grease filter. ^ To do this, pull out the deflector plate. ^ The position of the deflector plate can be brought forward by up to 35 mm using the adjusting screws on either side of the canopy.
  • Page 27: Set Up For Extraction Mode

    Installation ^ When connecting to existing Set up for extraction mode C 125 mm ducting, place the reducing collar supplied in the exhaust connection and secure the reducing collar to the exhaust ducting with a hose clip (see also "Connection for air extraction"). For new installations, 150 mm ducting is the preferred option as a reduction in duct diameter affects the...
  • Page 28: Set Up For Recirculation Mode

    “Warning and Safety instructions” before connecting to the electricity supply. ^ Plug the connection cable into a wall socket. For this, a conversion kit DUU 151, available from Miele, is required. You will also need a charcoal filter (see "Technical data").
  • Page 29: Connection For Air Extraction

    Connection for air extraction – The exhaust ducting should not be Important: To avoid the danger of kinked or compressed. toxic fumes, please observe the – Ensure that all connections are Warning and Safety instructions. strong and airtight. This is especially crucial when using the rangehood at the same time as –...
  • Page 30: Condensate Trap

    Connection for air extraction Condensate trap (optional accessory) For installations in areas where the exhaust ducting is exposed to cold temperatures, we recommend insulating the exhaust ducting and installing a condensate trap to collect and evaporate any condensate which may occur. Condensate traps are available for C 125 mm or C 150 mm ducting.
  • Page 31: Silencer

    Connection for air extraction Silencer (DASD 150, optional accessory) ...with air extraction: The silencer not only reduces noise from the fan, but also sounds from outside (e.g. traffic noise). To achieve even further reductions in For this reason, the silencer must be noise levels, a special silencer can be positioned as close as possible to where fitted in the ducting system.
  • Page 32: Electrical Connection

    Electrical connection If the switch is not accessible after All electrical work should be installation, an additional means of undertaken by a suitably qualified disconnection must be provided for all and competent person in strict poles. accordance with current national For extra safety, it is advisable to install and local safety regulations.
  • Page 33: After Sales Service

    In the event of a fault which you cannot correct yourself, please contact: – Miele You will find the telephone number and address of Miele on the back cover of the manual. Please quote the model and serial number when contacting Miele. These...
  • Page 34: Technical Data

    Level III ....200 m Intensive Setting ... 300 m Optional accessories for recirculation mode: - Conversion Kit DUU 151 - Miele charcoal filter DKF 13-1...
  • Page 36 Alteration rights reserved / 3013 M.-Nr. 09 725 790 / 00...

Table of Contents