DIGITAL VERNIER CALLIPER 0-300mm/0-12"
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO
MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
1.
SAFETY INSTRUCTIONS
WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to
when using tools and equipment.
DO NOT use if damaged.
Maintain calliper in good and clean condition for best performance.
Keep the work area clean, uncluttered and ensure there is adequate lighting.
Keep children and unauthorised persons away from the work area.
DO NOT use the calliper for any purpose other than for which it is designed.
DO NOT get calliper wet or use in damp or wet locations, or areas where there is condensation. Keep calliper clean
and dry using a dry cotton cloth only.
DO NOT dip or submerge the calliper in any type of liquid.
DO NOT expose calliper to bright sunlight or dust.
DO NOT disassemble. The calliper must be checked by qualified service personnel only.
DO NOT apply any voltage to the calliper i.e. with an electric marker pen.
The calliper is a precision instrument, treat with care, avoid using force and do not subject to knocks or shocks.
Use in reasonably constant temperature conditions of approximately 20
When not in use, turn off and store gauge in a safe, dry, childproof location.
2.
INTRODUCTION & SPECIFICATION
Hardened and tempered stainless steel digital calliper with satin finish. 11mm High figures in LCD display for ease of reading.
Metric and Imperial calibration with conversion between the two. Zero setting control allows for comparative measurement.
Supplied in carry-case.
Resolution
Range
Accuracy
Functions
Messages
Battery life
Battery
Operational Temperature range
2 3
1
11
6
1
Internal Measure
2
Metric/Imperial Selector
3
Locking Screw
4
ABS/0 Switch
5
LCD Display
6
External Measure
0.01mm (0.0005")
0-300mm (0-12")
±0.04mm/0.001"
Zero set, mm/inch select, incremental zero
Flashing display = replace battery
Approx. two years (approx. one year in continuous service)
LR44 - 1.5V
0 - 40°C
4
9
7 8
5
INSTRUCTIONS FOR:
AK9623EV
MODEL:
C.
°
7
On/Off Control
8
Zero Control
9
Battery Cover
10
Depth Measure
11
Step Measure
AK9623EV
10
Issue No: 1 - 24/09/08