free stats
Download Print this page
Sealey Power Products GSS150819SD Instructions Manual
Sealey Power Products GSS150819SD Instructions Manual

Sealey Power Products GSS150819SD Instructions Manual

Galvanized steel shed

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to
when building this shed.
Keep the work area clean, uncluttered and ensure there is adequate lighting.
Keep children and unauthorised persons away from the working area.
DO NOT use the shed for any purpose other than that for which it is designed.
Use appropriate safety clothing including eye protection.
Note! The assembly of this product will require assistance.
2. INTRODUCTION
Before commencing the assembly, we recommend that you read the instructions thoroughly. Your new shed
comes with all the holes pre drilled to make for fast easy assembly. We recommend that you assemble the
shed using a trestle table or sawhorses and planks. This will ensure that you are working off the ground and
make it easier for you. Assembly is a two person job and should not be attempted in windy conditions.
Sequence of operations.
2.1
Check all parts against the component list.
2.2
Assemble the rear wall panels.
2.3
Assemble the side wall panels.
2.4
Assemble the roof panels.
2.5
Assemble the front wall panels.
2.6
Assemble door.
2.7
Fit the panels together.
2.8
Prepare and fit to plinth slab.
© Jack Sealey Limited
INSTRUCTIONS FOR:
SHED 1.5 x 0.8 x 1.9m WITH SIDE DOOR.
GSS150819SD
MODEL No:
Original Language Version
GALVANIZED STEEL
GSS150819SD
Issue: 1 - 20/08/12

Advertisement

loading

Summary of Contents for Sealey Power Products GSS150819SD

  • Page 1 GSS150819SD MODEL No: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
  • Page 2 Check contents: Lay out all components with the part numbers facing upwards and check off against the parts lists on the next four pages. In the unlikely event of a missing component please contact you local Sealey dealer. Original Language Version ©...
  • Page 3 1980 x 770 sheet 1900-1980 x 770 sheet 80-160 x 770 sheet 855 x 770 sheet 1900 x 770 sheet 1900 x 770 sheet 1780 x 720 channel 1508 Original Language Version © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 4 Original Language Version © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 5 Ø3 x 10mm Rivet Ø4 x 10mm Rivet Pad shoot bolt Keeper Part No 70 Part No 71 Mid height wall bracket Part No 72 Original Language Version © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 6 Please note some component descriptions may differ in manual text to listings, always use pictures from listings to double check component identity. ie M8 fixings may be supplied in lieu of 5/16”. © Jack Sealey Limited Original Language Version GSS150819SD Issue: 1 - 20/08/12...
  • Page 7: Parts Diagram

    6. PARTS DIAGRAM Original Language Version © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 8 7. ASSEMbLY ASSEMbLE THE REAR WALL PANELS 7.1.1 You will find it easier to assemble the shed using trestles with timber studding of equal or greater panel length. Trestles can be supplied separately by your Jack Sealey dealership. Attach the studding to trestles with equal overhang using nylon cable ties or similar “safe” method. 7.1.2 Place panel 1A and 1L on your work table and join them together with the 10mm long self tapping screws.
  • Page 9 7.1.4 Fit item 38A the mid height wall channel to the panel and position it by the pre-punched holes and 10mm long self tapping screws. Note this channel is fitted with the flat face uppermost, ie. nearest the “top”. 7.1.5 With self tapping screws fix items 20B and 20C to top and bottom edges. Original Language Version © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 10 Fit item 32D the mid height wall channel to the panel and position it by the pre-punched holes and 10mm long self tapping screws. Note this channel is fitted with the flat face uppermost, ie. nearest the “top”. 7.2.4 With self tapping screws fix item 21B to bottom edge, but do not screw fix item 21A to top edge at this stage,see places marked with asterisk *. Original Language Version © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 11 See the pre-punched holes and both diagrams. 7.3.2 Fit top and bottom channels 20B and 20C to panels by firstly sliding and finally tapping into place. Note that the smaller flange on the channels should always be adjacent to the outside face of the panel. The outside face is the diagram. Fix both with 10mm long self tapping screws except for positions marked with asterisk *, which are not fixed at this stage. © Jack Sealey Limited Original Language Version GSS150819SD Issue: 1 - 20/08/12...
  • Page 12 7.3.3 Fit item 38B the mid height wall channel to the panel and position it by the pre-punched holes and 10mm long self tapping screws. Note this channel is fitted with the flat face uppermost, ie. nearest the “top”. © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 13 Place both panels item 3 on your work table and join them together with the 10mm long self tapping screws. See the pre-punched holes and both diagrams. 7.4.2 Fit top and bottom channels item 20A to panels by firstly sliding and finally tapping into place as previously explained in 7.1.3. Note that the smaller flange on the channels should always be adjacent to the outside face of the panel. The outside face is the top face in both diagrams. Original Language Version GSS150819SD Issue: 1 - 20/08/12 © Jack Sealey Limited...
  • Page 14 7.4.3 Fit item 50 (angles) to each edge, refer to diagram this page for flange orientation. Fix with 10mm long self tapping screws. Original Language Version © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 15 Attach the side wall 2E to the rear wall 1A & 1L, then the front wall 9A & 9S. Fix all walls with the 10mm long self tapping screws. Original Language Version © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 16 INSTALL THE DOOR FRAME 7.6.1 Install the front frame per following diagrams. The door mullion sections are fixed with 16mm long self tapping screws. Do not fix self tapping screws marked * in enlarged ballooned views at this stage. FIX DOOR MULLION SECTIONS WITH SIX 16mm LONG SELF TAPPING SCREWS Original Language Version © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 17 7.6.2 Fit the panel item 2F and the channel item 21H, fix with 16mm long self tapping screws. Fix the channel item 21H with 16mm long self tapping screws. 7.6.3 Slide and tap on top channel item 21J, but do not screw fix at this stage. Original Language Version © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 18: Install The Door

    Fit the pre assembled door item 5C to the rear panel via the hinges. Fix hinges into pre-punched holes with 4mm diameter rivets. Check action of door before crimping rivets. 7.7.2 Fit the shoot bolt item 70 and the bolt keeper item 71 and fix with 10mm long self tapping screws or 4mm diameter rivets. (fitting method A or B) Original Language Version © Jack Sealey Limited GSS150819SD Issue: 1 - 20/08/12...
  • Page 19 With the shed located centrally about the plinth slab, position the 6 anchor steel angles, M8 machine screw fix to internal compartment. This will require “spotting” and drilling 8mm diameter holes through to shed panels. Spot through holes to plinth slab, remove anchor angles and masonry drill slab for anchor bolts. Please note anchor bolts and M8 machine screws are supplied, see “FITTINGS PACK”. 7.8.3 Insert anchor bolts, re-fit steel angles and anchor shed to plinth slab. Original Language Version GSS150819SD Issue: 1 - 20/08/12 © Jack Sealey Limited...
  • Page 20 WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole UK Distributor, Sealey Group, www.sealey.co.uk...