SNMP Trap ID: 560922652
User Action:
1. Reset the BMC on indicated compute node.
2. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
3. If the event persists, replace the indicated compute node. (Service technician only)
4. If the event persists, please consult with technical service.
• 216F001D: Node 2 BMC: Slot Or Connector, Fault Status asserted was asserted.
The BMC on indicated compute node unable to response to the initial request in 2 minutes after the
compute node inserted.
Severity: Error
Alert Category: Node - Node event
SNMP Trap ID: 560922653
User Action:
1. Reset the BMC on indicated compute node.
2. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
3. If the event persists, replace the indicated compute node. (Service technician only)
4. If the event persists, please consult with technical service.
• 216F001E: Node 3 BMC: Slot Or Connector, Fault Status asserted was asserted.
The BMC on indicated compute node unable to response to the initial request in 2 minutes after the
compute node inserted.
Severity: Error
Alert Category: Node - Node event
SNMP Trap ID: 560922654
User Action:
1. Reset the BMC on indicated compute node.
2. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
3. If the event persists, replace the indicated compute node. (Service technician only)
4. If the event persists, please consult with technical service.
• 216F001F: Node 4 BMC: Slot Or Connector, Fault Status asserted was asserted.
The BMC on indicated compute node unable to response to the initial request in 2 minutes after the
compute node inserted.
Severity: Error
Alert Category: Node - Node event
SNMP Trap ID: 560922655
User Action:
1. Reset the BMC on indicated compute node.
2. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
3. If the event persists, replace the indicated compute node. (Service technician only)
4. If the event persists, please consult with technical service.
.