free stats
Sealey SDH102.V2 Quick Start Manual

Sealey SDH102.V2 Quick Start Manual

10l dehumidifier

Advertisement

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Do not cover
Refer to
instruction
manual
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any
other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate
safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend
that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a
supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current
Device by contacting your Sealey stockist. You must also read and understand the following instructions concerning electrical safety.
1.1.1.
The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and
the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2. and
use a Portable Appliance Tester.
1.1.4.
Ensure that cables are always protected against short circuit and overload.
1.1.5.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure
that none are loose.
1.1.6.
IMPORTANT: Ensure that the voltage marked on the appliance matches the power supply to be used.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or
8
replaced by a qualified electrician. When a BS1363/A UK 3 pin plug is damaged, cut the cable just above
the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a)
Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b)
Connect the BROWN live wire to the live terminal 'L'.
c)
Connect the BLUE neutral wire to the neutral terminal 'N'.
d)
After wiring, check that there are no bare wires, that all wires have been correctly connected, that
the cable outer insulation extends beyond the cable restraint and that the restraint is tight.
1.1.7.
If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use
of 2.5mm² section cable.
1.2.
GENERAL SAFETY
Check that the dehumidifier is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
9
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
DO NOT stand or place any object less than 30cm from the front of the unit, 30cm from the rear and sides of the unit, and 50cm above
8
the unit.
DO NOT obstruct the air intakes or outlets of the dehumidifier, and DO NOT cover with washed clothes.
8
DO NOT place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.
8
DO NOT operate the dehumidifier when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT switch the dehumidifier off by disconnecting it from the mains. ALWAYS switch to the "OFF" position first.
8
DO NOT remove the float lever from the water collection tank.
8
DO NOT connect or disconnect the plug from the mains with wet hands.
8
DO NOT use the dehumidifier outside.
8
DO NOT place the dehumidifier near to radiators or other heating appliances.
8
DO NOT tip to any side as escaping water could damage the appliance.
8
ALWAYS discard the water from the collection tank, DO NOT use it for any other purpose.
9
Only operate the dehumidifier on a level and stable surface.
9
To prevent water from freezing, DO NOT use the dehumidifier at ambient temperatures below 5°C.
9
Ensure that heating appliances are not exposed to the flow of air from the dehumidifier.
9
© Jack Sealey Limited
10L DEHUMIDIFIER
MODEL NO:
Indoor use only
Caution:
risk of fire
Original Language Version
SDH102.V2
This appliance contains approximately 45g
of R290 refrigerant gas.
Appliance shall be installed, operated and
stored in a room with a floor area larger than
4m².
Replacement fuse
rating: 3A
SDH102.V2 Issue 1 21/07/22

Advertisement

Table of Contents
loading

Summary of Contents for Sealey SDH102.V2

  • Page 1 SDH102.V2 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 WARNING: Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring ‰ the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants. WARNING: If you don’t understand something or need help, please contact Sealey. ‰ 1.3.1. Checks to the area 1.3.1.1. Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized.
  • Page 3: Specification

    80% is reached the value set cycles back to 30%. 4.3.2. If the button is held down continuously the unit will display the current ambient temperature. 4.4. TIMER 4.4.1. The timer can be set from 0-24 hours in 1 hour increments. Set the value to “00” to cancel the timer function. 4.4.2. After the timer is set, the timer LED is on during the timing period. After the timing is over, the timer LED turns off. SDH102.V2 Issue 1 21/07/22 Original Language Version © Jack Sealey Limited...
  • Page 4: Continuous Drainage

    Humidity sensor problem Change a sensor Environmental humidity is below 20% Unit shuts down. Environmental humidity is above 90% Low temperature protection, the environmental temperature<5 High temperature protection, the environmental temperature>38 SDH102.V2 Issue 1 21/07/22 Original Language Version © Jack Sealey Limited...
  • Page 5: Weee Regulations

    Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR...

Table of Contents