Lenovo ThinkSystem SR850 V3 System Configuration Manual

Lenovo ThinkSystem SR850 V3 System Configuration Manual

Hide thumbs Also See for ThinkSystem SR850 V3:
Table of Contents

Advertisement

Quick Links

ThinkSystem SR850 V3
System Configuration Guide
Machine Type: 7D96, 7D97, and 7D98

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo ThinkSystem SR850 V3

  • Page 1 ThinkSystem SR850 V3 System Configuration Guide Machine Type: 7D96, 7D97, and 7D98...
  • Page 2 Before using this information and the product it supports, be sure to read and understand the safety information and the safety instructions, which are available at: https://pubs.lenovo.com/safety_documentation/ In addition, be sure that you are familiar with the terms and conditions of the Lenovo warranty for your server, which can be found at: http://datacentersupport.lenovo.com/warrantylookup First Edition (May 2023) ©...
  • Page 3: Table Of Contents

    Tech Tips ....2 Identify the server and access the Lenovo XClarity Controller ....
  • Page 4 ThinkSystem SR850 V3 System Configuration Guide...
  • Page 5: Safety

    Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. © Copyright Lenovo 2023...
  • Page 6: Safety Inspection Checklist

    1 & IEC 60950-1, the standard for Safety of Electronic Equipment within the Field of Audio/Video, Information Technology and Communication Technology. Lenovo assumes you are qualified in the servicing of equipment and trained in recognizing hazards energy levels in products. Access to the equipment is by the use of a tool, lock and key, or other means of security, and is controlled by the authority responsible for the location.
  • Page 7 Click Power ➙ Power Cables to see all line cords. • Make sure that the insulation is not frayed or worn. 3. Check for any obvious non-Lenovo alterations. Use good judgment as to the safety of any non-Lenovo alterations.
  • Page 8 ThinkSystem SR850 V3 System Configuration Guide...
  • Page 9: Chapter 1. Introduction

    Chapter 1. Introduction The ThinkSystem SR850 V3 server (Types 7D96, 7D97, and 7D98) is a 2U rack server designed for high- volume network transaction processing. This high-performance, multi-core server is ideally suited for networking environments that require superior microprocessor performance, input/output (I/O) flexibility, and high manageability.
  • Page 10: Tech Tips

    The server provides a QR code on the system service label, which is on the cover of the server, that you can scan using a QR code reader and scanner with a mobile device to get quick access to the Lenovo Service Information website.
  • Page 11: Specifications

    Lenovo Product Security Incident Response Team (PSIRT) to investigate and provide information to our customers so they may put mitigation plans in place as we work toward providing solutions. The list of current advisories is available at the following site: https://datacentersupport.lenovo.com/product_security/home...
  • Page 12 – 960 GB The following form factors are supported: • 42 mm (2242) • 60 mm (2260) • 80 mm (2280) • 110 mm (22110) For a list of supported M.2 drives, see https://serverproven.lenovo.com ThinkSystem SR850 V3 System Configuration Guide...
  • Page 13 – ConnectX-7 NDR200 QSFP 2-port adapter or ConnectX-7 NDR400 QSFP 1-port adapter with Active Optical Cable For a list of supported drives, see https://serverproven.lenovo.com Expansion slots • Up to twelve PCIe slots (depending on the server model): – Slot 3-14 •...
  • Page 14 • Lenovo XClarity Controller (XCC), which provides service processor control and monitoring functions, video controller, and remote keyboard, video, mouse, and remote drive capabilities. – The server supports Lenovo XClarity Controller 2 (XCC2). For additional information about Lenovo XClarity Controller 2 (XCC2), refer to https://sysmgt.lenovofiles.com/help/topic/lxcc_frontend/lxcc_overview.html...
  • Page 15 • ThinkSystem 4350-8i SAS/SATA PCIe Gen3 12Gb Internal HBA • ThinkSystem 4350-16i SAS/SATA PCIe Gen3 12Gb Internal HBA For more information about the RAID/HBA adapters, see Lenovo ThinkSystem RAID Adapter and HBA Reference System fan The server supports one of the following fan types: •...
  • Page 16: Mechanical Specifications

    Up to 40 kg (88.18 lb), depending on the server configuration Environmental specifications Summary of the environmental specifications of server. Depending on the model, some features might not be available, or some specifications might not apply. ThinkSystem SR850 V3 System Configuration Guide...
  • Page 17 Lenovo recommends that you consult with qualified experts in this field to determine whether you are in compliance with the applicable regulations.
  • Page 18 • Keep ambient temperature to 25°C or lower when one or more of the following components are installed. – Processors with TDP less than or equal to 165W, four 2.5-inch drives, and FHFL PCIe adapters – DRAM DIMMs with capacity 256 GB, and eight 2.5-inch drives – Double-wide GPU adapters ThinkSystem SR850 V3 System Configuration Guide...
  • Page 19 If Lenovo determines that the levels of particulates or gases in your environment have caused damage to the device, Lenovo may condition provision of repair or replacement of devices or parts on implementation of appropriate remedial measures to mitigate such environmental contamination.
  • Page 20: Management Options

    Management options The XClarity portfolio and other system management options described in this section are available to help you manage the servers more conveniently and efficiently. ThinkSystem SR850 V3 System Configuration Guide...
  • Page 21 • Redfish API Usage and downloads https://sysmgt.lenovofiles.com/help/topic/lxcc_frontend/lxcc_overview.html Application that reports the XCC events to local OS system log. Interface • CLI application Lenovo XCC Logger Utility Usage and downloads https://sysmgt.lenovofiles.com/help/topic/lxcc-logger-frontend/lxcc-logger-overview.html Centralized interface for multi-server management. Interface • Web GUI interface •...
  • Page 22 Important: Lenovo XClarity Provisioning Manager (LXPM) supported version varies by product. All versions of Lenovo XClarity Provisioning Manager are referred to as Lenovo XClarity Provisioning Manager and LXPM in this document, unless specified otherwise. To see the LXPM version supported by your server, go to https:// sysmgt.lenovofiles.com/help/topic/lxpm_frontend/lxpm_product_page.html...
  • Page 23 1. Most options can be updated through the Lenovo tools. Some options, such as GPU firmware or Omni- Path firmware require the use of supplier tools. 2. The server UEFI settings for option ROM must be set to Auto or UEFI to update firmware using Lenovo XClarity Administrator, Lenovo XClarity Essentials, or Lenovo XClarity Controller.
  • Page 24 ThinkSystem SR850 V3 System Configuration Guide...
  • Page 25: Chapter 2. Server Components

    VGA connector Connect a monitor to this connector. External diagnostics handset connector Connect the external diagnostics handset to this connector. See “External diagnostics handset” in ThinkSystem SR850 V3 User Guide or Hardware Maintenance Guide for more details. © Copyright Lenovo 2023...
  • Page 26 ID button, the state of the system ID LED changes. The LED can be changed to on, blinking, or off. You can also use the Lenovo XClarity Controller or a remote management program to change the state of the system ID LED to assist in visually locating the server among other servers.
  • Page 27 In this mode, the USB port is always solely connected to Lenovo XClarity Controller. • Shared mode: owned by BMC In this mode, connection to the USB port is shared by the server and Lenovo XClarity Controller, while the port is switched to Lenovo XClarity Controller.
  • Page 28: Rear View

    The rear of the server provides access to several components, including the power supplies, PCIe risers, and Ethernet port. The ThinkSystem SR850 V3 rear view varies by model. Refer to the rear view specific to each model to identify the components.
  • Page 29 PCIe riser 1 (PCIe slot 3-5) Install PCIe adapters into these slots. See the following table for PCIe slots corresponding to the PCIe risers. x8/x16/x16 PCIe G4 7mm/x16 PCIe G4 x16/x16 PCIe G5 7mm/x16 PCIe G5 PCIe slot Riser 1/3 FHFL Riser 1 FHHL Riser 1/3 FHFL Riser 1 FHHL...
  • Page 30 XCC system management port. XCC system management port (1 GB RJ-45) The server has a 1 GB RJ-45 connector dedicated to Lenovo XClarity Controller (XCC) functions. Through the system management port, you can access the Lenovo XClarity Controller directly by connecting your laptop to the management port using an Ethernet cable.
  • Page 31: Rear View Of The Sever Model With Four Pcie

    Figure 6. OCP module with two Ethernet connectors Figure 7. OCP module with four Ethernet connectors Rear view of the sever model with four PCIe risers This section contains information on the rear view of the sever model with four PCIe risers. Figure 8.
  • Page 32 • OCP module with two or four extra Ethernet connectors for network connections. One of the Ethernet ports on the OCP module can also function as a management port with shared management capacity. If ThinkSystem SR850 V3 System Configuration Guide...
  • Page 33 XCC system management port. XCC system management port (1 GB RJ-45) The server has a 1 GB RJ-45 connector dedicated to Lenovo XClarity Controller (XCC) functions. Through the system management port, you can access the Lenovo XClarity Controller directly by connecting your laptop to the management port using an Ethernet cable.
  • Page 34: Top View

    Figure 12. OCP module with four Ethernet connectors Top view This section contains information on the top view of the server. The ThinkSystem SR850 V3 top view varies by model. Refer to the top view specific to each model to identify the components. •...
  • Page 35: Top View Of The Sever Model With Four Pcie

    Figure 13. Top view of the sever model with three PCIe risers Table 5. Components on the top view of the sever model with three PCIe risers Drive backplanes Intrusion switch Fan cage and fans Power backplane System board assembly Power supply bays Memory modules PCIe risers...
  • Page 36 Power backplane System board assembly Power supply bays Memory modules PCIe risers Processors Note: The illustration shows the location of certain parts. Some parts may not be supported at the same time within certain configuration(s). ThinkSystem SR850 V3 System Configuration Guide...
  • Page 37: Front I/O Module

    Note: This is the only USB port that supports USB automation update of the firmware and RoT security module. Connection to Lenovo XClarity Controller is primarily intended for users with a mobile device running the Lenovo XClarity Controller mobile application. When a mobile device is connected to this USB port, an Ethernet over USB connection is established between the mobile application running on the device and the Lenovo XClarity Controller.
  • Page 38 In this mode, the USB port is always solely connected to Lenovo XClarity Controller. • Shared mode: owned by BMC In this mode, connection to the USB port is shared by the server and Lenovo XClarity Controller, while the port is switched to Lenovo XClarity Controller.
  • Page 39: System-Board-Assembly Layout

    Description Status Color Action An error has been detected on the server. Causes might include one or more of the following errors: • The temperature of the server reached the non-critical temperature threshold. • The voltage of the server reached the Check the Event log to determine the exact Yellow non-critical voltage threshold.
  • Page 40: System-Board-Assembly Connectors

    For more information about the LEDs that are available on the system board assembly, see “System-board- assembly LEDs” on page System-board-assembly connectors The following illustrations show the internal connectors on the system board assembly. ThinkSystem SR850 V3 System Configuration Guide...
  • Page 41 Figure 17. System-board-assembly connectors Table 8. System-board-assembly connectors Fan 6 connector PCIe riser 3/D connector Backplane 6 power connector OCP slot 2 connector Power backplane sideband connector Fan 5 connector Backplane 5 power connector PCIe riser C power connector Firmware and RoT security module connector Fan 4 connector Backplane 4 power connector MicroSD socket...
  • Page 42: System-Board-Assembly Switches

    2. Any system-board-assembly switch or jumper block that is not shown in the illustrations in this document are reserved. Note: If there is a clear protective sticker on the top of the switch blocks, you must remove and discard it to access the switches. ThinkSystem SR850 V3 System Configuration Guide...
  • Page 43 Figure 18. System-board-assembly switches SW3 switch block The following table describes the functions of the SW3 switch block on the system board assembly. Table 9. System-board-assembly SW3 switch block description Default position Description Switch number Reserved Changing this switch to the On position to resets the RTC. A momentary toggle is all that is required.
  • Page 44: System Leds And Diagnostics Display

    See the following section for information on available system LEDs and diagnostics display. Drive LEDs This topic provides information on drive LEDs. The following table describes the problems that are indicated by drive activity LED and drive status LED. Figure 19. Drive LEDs ThinkSystem SR850 V3 System Configuration Guide...
  • Page 45: Front I/O Module Leds

    Table 11. Drive LEDs Description Drive activity Each hot-swap drive comes with an activity LED. When this LED is flashing, it indicates that the LED (green) drive is in use. The drive status LED indicates the following status: • The LED is lit: the drive has failed. Drive status LED (yellow) •...
  • Page 46: Power Supply Leds

    ID button, the state of the system ID LED changes. The LED can be changed to on, blinking, or off. You can also use the Lenovo XClarity Controller or a remote management program to change the state of the system ID LED to assist in visually locating the server among other servers.
  • Page 47 • Off: The power supply is working normally Fault LED • Amber: The power supply may have failed. Dump the FFDC log from the system and contact Lenovo back end support team for PSU data log reviewing. CRPS power supply LED Figure 22. CRPS power supply LED...
  • Page 48: Rear System Leds

    This topic provides information on system LEDs on the rear of the server. Figure 23. System LEDs on the rear view - server model with three PCIe risers Figure 24. System LEDs on the rear view - server model with four PCIe risers ThinkSystem SR850 V3 System Configuration Guide...
  • Page 49: System-Board-Assembly Leds

    Table 15. System LEDs on the rear view Description Action A system ID button with LED is also located on the front System ID LED This LED helps you to visually of the server. You can press the system ID button to turn (blue) locate the server.
  • Page 50 Figure 25. System-board-assembly LEDs ThinkSystem SR850 V3 System Configuration Guide...
  • Page 51 Table 16. System-board-assembly LEDs Description Action LED on: an error has been detected on the server. Causes might include one or more of the following errors: • The temperature of the server reached the non-critical temperature threshold. • The voltage of the server System error LED Check system logs or internal error LEDs to identify the reached the non-critical...
  • Page 52 RoT security module are installed correctly. (Trained technician only) Reinstall them if needed. 3. If the problem remains, contact Lenovo Support. If the PCH heartbeat LED is always off or always on, do the following: 1. Check and ensure that the system I/O board and the firmware and RoT security module are installed correctly.
  • Page 53: Xcc System Management Port Leds

    FPGA heartbeat second): FPGA is working LED (green) 1. Replace the processor board. normally. 2. If the problem remains, contact Lenovo Support. • On or off: FPGA is not working. LED on: an error has occurred to Processor 1 error the processor the LED Replace the processor.
  • Page 54: External Diagnostics Handset

    External diagnostics connector This connector is located on the front of the server, and is used to connect an external diagnostics handset. Note: When unplugging the external diagnostics handset, see the following instructions: ThinkSystem SR850 V3 System Configuration Guide...
  • Page 55 Press the plastic clip on the plug forward. Hold the clip and remove the cable from the connector. Display panel overview The diagnostics device consists of an LCD display and 5 navigation buttons. LCD display Scroll buttons (up/down/left/right) Press the scroll buttons to locate and select system information.
  • Page 56 Following is the list of available options. Switch between an option and the subordinate information entries with the select button, and switch among options or information entries with the scroll buttons. Depending on the model, the options and entries on the LCD display might be different. ThinkSystem SR850 V3 System Configuration Guide...
  • Page 57 Home Menu (System Status Dashboard) Home Menu Example System name System status Active alert quantity Temperature Power consumption Checkpoint code Active Alerts Sub Menu Example Home screen: Active error quantity Note: The “Active Alerts” menu displays only the quantity 1 Active Alerts of active errors.
  • Page 58 • Static IPv6 IP IPv4 Network Mask: • Current IPv6 Gateway x.x.x.x • IPv6 DNS IPv4 Default Gateway: Note: Only the MAC address that is currently in use is x.x.x.x displayed (extension or shared). ThinkSystem SR850 V3 System Configuration Guide...
  • Page 59 System Environmental Information Sub Menu Example Ambient Temp: 24 C Exhaust Temp: 30 C • Ambient temperature CPU1 Temp: 50 C • Exhaust temperature PSU1: Vin= 213 w • CPU temperature Inlet= 26 C • PSU status FAN1 Front: 21000 RPM •...
  • Page 60 ThinkSystem SR850 V3 System Configuration Guide...
  • Page 61: Chapter 3. Parts List

    2. Click Parts. 3. Enter the serial number to view a listing of parts for your server. It is highly recommended that you check the power summary data for your server using Lenovo Capacity Planner before purchasing any new parts.
  • Page 62 Tier 1 CRU at your request with no service agreement, you will be charged for the installation. • Tier 2 customer replaceable unit (CRU): You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your server.
  • Page 63 For more information about ordering parts: 1. Go to and navigate to the support page for your server. http://datacentersupport.lenovo.com 2. Click Parts. 3. Enter the serial number to view a listing of parts for your server. Front top cover √...
  • Page 64: Power Cords

    Note: * For memory modules in memory module slot 1-32 when 2U performance PHM are installed. Power cords Several power cords are available, depending on the country and region where the server is installed. To view the power cords that are available for the server: ThinkSystem SR850 V3 System Configuration Guide...
  • Page 65 1. Go to: http://dcsc.lenovo.com/#/ 2. Click Preconfigured Model or Configure to order. 3. Enter the machine type and model for your server to display the configurator page. 4. Click Power ➙ Power Cables to see all line cords. Notes: • For your safety, a power cord with a grounded attachment plug is provided to use with this product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet.
  • Page 66 ThinkSystem SR850 V3 System Configuration Guide...
  • Page 67: Chapter 4. Unboxing And Setup

    They might be required to receive warranty service. Identify the server and access the Lenovo XClarity Controller This section contains instruction on how to identify your server and where to find the Lenovo XClarity Controller access information.
  • Page 68 Lenovo XClarity Controller network access label In addition, the Lenovo XClarity Controller network access label is attached to the pull-out information tab located near the lower right corner in the front of the chassis, with MAC address accessible with a pull.
  • Page 69: Server Setup Checklist

    Service Label and QR code In addition, the system Service Label located on the surface of the front top cover, provides a quick response (QR) code for mobile access to service information. You can scan the QR code with a mobile device using a QR code reader application and get quick access to the Service Information web page.
  • Page 70 • You can press the power button. • The server can restart automatically after a power interruption. • The server can respond to remote power-on requests sent to the Lenovo XClarity Controller. Note: You can access the management processor interface to configure the system without powering on the server.
  • Page 71 6. Install the applications and programs for which the server is intended to be used. Chapter 4 Unboxing and setup...
  • Page 72 ThinkSystem SR850 V3 System Configuration Guide...
  • Page 73: Chapter 5. System Configuration

    The following methods are available to set the network connection for the Lenovo XClarity Controller if you are not using DHCP: • If a monitor is attached to the server, you can use Lenovo XClarity Provisioning Manager to set the network connection.
  • Page 74: Set Front Usb Port For Lenovo Xclarity Controller

    ID button. To connect using the Lenovo XClarity Administrator Mobile app: 1. Connect the USB cable of your mobile device to the Lenovo XClarity Controller USB connector on the server. 2. On your mobile device, enable USB tethering.
  • Page 75: Update The Firmware

    Windows Server, Red Hat Enterprise Linux (RHEL) and SUSE Linux Enterprise Server (SLES) operating system distributions. Machine-type-specific firmware-only Static Bundles (Service Packs) are also available. Firmware updating tools See the following table to determine the best Lenovo tool to use for installing and setting up the firmware: Chapter 5 System configuration...
  • Page 76 Selected I/ √ √ Lenovo XClarity band O devices Integrator (LXCI) for VMware vCenter Off-Target In-band All I/O √ √ √ Lenovo XClarity devices Integrator (LXCI) for Out-of- Microsoft Windows band Admin Center On-Target Off-Target ThinkSystem SR850 V3 System Configuration Guide...
  • Page 77 • Lenovo XClarity Controller If you need to install a specific update, you can use the Lenovo XClarity Controller interface for a specific server. Notes: – To perform an in-band update through Windows or Linux, the operating system driver must be installed and the Ethernet-over-USB (sometimes called LAN over USB) interface must be enabled.
  • Page 78: Configure The Firmware

    Several options are available to install and set up the firmware for the server. Important: Lenovo does not recommend setting option ROMs to Legacy, but you can conduct this setting if necessary. Note that this setting prevents UEFI drivers for the slot devices from loading, which may cause negative side effects to Lenovo software, such as LXCA, OneCLI, and XCC.
  • Page 79: Memory Module Configuration

    In addition, you can choose to make the text-based interface the default interface that is displayed when you start LXPM. To do this, go to Lenovo XClarity Provisioning Manager ➙ UEFI Setup ➙ System Settings ➙ <F1>Start Control ➙ Text Setup. To start the server with Graphic User Interface, select Auto or Tool Suite.
  • Page 80: Enable Software Guard Extensions (Sgx)

    OS logical drives or volumes. An introduction to RAID is available at the following Lenovo Press website: https://lenovopress.lenovo.com/lp0578-lenovo-raid-introduction Detailed information about RAID management tools and resources is available at the following Lenovo Press website: https://lenovopress.lenovo.com/lp0579-lenovo-raid-management-tools-and-resources Notes: •...
  • Page 81: Deploy The Operating System

    • Multi-server Available tools: – Lenovo XClarity Administrator http://sysmgt.lenovofiles.com/help/topic/com.lenovo.lxca.doc/compute_node_image_deployment.html – Lenovo XClarity Essentials OneCLI http://sysmgt.lenovofiles.com/help/topic/toolsctr_cli_lenovo/onecli_r_uxspi_proxy_tool.html – Lenovo XClarity Integrator deployment pack for SCCM (for Windows operating system only) https://sysmgt.lenovofiles.com/help/topic/com.lenovo.lxci_deploypack_sccm.doc/dpsccm_c_endtoend_ deploy_scenario.html • Single-server Available tools: – Lenovo XClarity Provisioning Manager “OS Installation” section in the LXPM documentation compatible with your server at https:// sysmgt.lenovofiles.com/help/topic/lxpm_frontend/lxpm_product_page.html...
  • Page 82: Back Up The Server Configuration

    Make sure that you create backups for the following server components: • Management processor You can back up the management processor configuration through the Lenovo XClarity Controller interface. For details about backing up the management processor configuration, see: “Backing up the BMC configuration” section in the XCC documentation compatible with your server at https://sysmgt.lenovofiles.com/help/topic/lxcc_frontend/lxcc_overview.html...
  • Page 83: Appendix A. Getting Help And Technical Assistance

    Appendix A. Getting help and technical assistance If you need help, service, or technical assistance or just want more information about Lenovo products, you will find a wide variety of sources available from Lenovo to assist you. On the World Wide Web, up-to-date information about Lenovo systems, optional devices, services, and support are available at: http://datacentersupport.lenovo.com...
  • Page 84: Collecting Service Data

    Collecting service data To clearly identify the root cause of a server issue or at the request of Lenovo Support, you might need collect service data that can be used for further analysis. Service data includes information such as event logs and hardware inventory.
  • Page 85: Contacting Support

    Support when certain serviceable events occur in Lenovo XClarity Administrator and the managed endpoints. You can choose to send diagnostic files to Lenovo Support using Call Home or to another service provider using SFTP. You can also manually collect diagnostic files, open a problem record, and send diagnostic files to the Lenovo Support.
  • Page 86 ThinkSystem SR850 V3 System Configuration Guide...
  • Page 87: Appendix B. Documents And Supports

    • UEFI Manual – UEFI setting introduction Support websites This section provides driver and firmware downloads and support resources. Support and downloads • Drivers and Software download website for ThinkSystem SR850 V3 – https://datacentersupport.lenovo.com/tw/en/products/servers/thinksystem/sr850v3/7d96/downloads/ driver-list/ • Lenovo Data Center Forum –...
  • Page 88 • Operating System Installation Instructions – https://pubs.lenovo.com/#os-installation • Submit an eTicket (service request) – https://support.lenovo.com/servicerequest • Subscribe to Lenovo Data Center Group product notifications (Stay up to date on firmware updates) – https://datacentersupport.lenovo.com/solutions/ht509500 ThinkSystem SR850 V3 System Configuration Guide...
  • Page 89: Appendix C. Notices

    Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead.
  • Page 90: Trademarks

    (TBW). A device that has exceeded this limit might fail to respond to system-generated commands or might be incapable of being written to. Lenovo is not responsible for replacement of a device that has exceeded its maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the device.
  • Page 91: Taiwan Region Bsmi Rohs Declaration

    Taiwan Region BSMI RoHS declaration Taiwan Region import and export contact information Contacts are available for Taiwan Region import and export information. Appendix C. Notices...