Connecting the Switch to the ACI Fabric
Before you begin
The console device must support VT100 terminal emulations and asynchronous transmissions.
Step 1
Configure the terminal emulator program to match each of the following default port characteristics:
• 9600 baud
• 8 data bits
• 1 stop bit
• No parity
Step 2
Insert the RJ-45 connector on the interface cable found in the accessory kit into the RS-232 port on the switch and insert
the DB-9 connector on the other end of the cable to the serial port on the console device.
What to do next
You can now perform the initial configuration for the switch (see the Cisco ACI Getting Started Guide).

Setting Up an Optional Management Connection

You can optionally set up an out-of-band management connection for monitoring and troubleshooting purposes.
To do this, depending on your switch, you connect either the RJ-45 management port or the SFP management
port on the switch to an external hub, switch, or router.
Before you begin
To prevent an IP address conflict, you must complete the initial configuration for the switch and establish an
IP address before you create the management connection.
Step 1
Connect the interface cable to a management port on the switch.
Step 2
Connect the other end of the cable to an external hub, switch, or router.

Maintaining Transceivers and Optical Cables

Transceivers and fiber-optic cables must be kept clean and dust free to maintain high signal accuracy and
prevent damage to the connectors. Contamination increases attenuation (loss of light) and should be below
0.35 dB.
Consider the following maintenance guidelines:
• Transceivers are static sensitive. To prevent ESD damage, wear an ESD-preventative wrist strap that is
connected to the grounded chassis.