Page 4
Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten. Bu ürünü kurmadan önce güvenlik bilgilerini okuyun. Youq mwngz yungh canjbinj neix gaxgonq, itdingh aeu doeg aen canjbinj soengq cungj vahgangj ancien suisik. RackSwitch G8296 Installation Guide...
Page 6
Overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions. To avoid these hazards, ensure that your system electrical requirements do not exceed branch circuit protection requirements. Refer to the information that is provided with your device for electrical specifications. RackSwitch G8296 Installation Guide...
Page 8
4. Attach signal cables to other 2. Remove the signal cables from the devices. connectors. 5. Connect power cords to their 3. Remove all cables from the sources. devices. 6. Turn ON all the power sources. RackSwitch G8296 Installation Guide...
Multiple devices extended into the service position can cause your rack cabinet to tip. • If you are not using the Lenovo 9308 rack cabinet, securely anchor the rack cabinet to ensure its stability. Other Important Safety Notices Important This product is also designed for IT power distribution systems with phase-to-phase voltage of 230V.
Other Important Safety Notices ....9 Chapter 1. The RackSwitch G8296 ....15 Introduction .
Page 12
Removing the G8296 from a Lenovo System x or Power Rack..63 Removing the G8296 from a Lenovo NeXtScale Rack ..65 Removing the Air-Duct Option ....67 Replacing the G8296 .
If you are using a Linux operating system, insert the CD into the CD or DVD drive and run the following command from the mnt/cd directory: sh.linux.sh When the CD is mounted, open the directories and documents that support your product. RackSwitch G8296 Installation Guide...
Related Documentation Additional or updated product documents may be available from the Lenovo website. Such documents may cover features not described in the original documentation that comes with the switch, or may include technical updates or corrections. You can obtain up-to-date information on the Lenovo support website: http://support.lenovo.com/...
USB drive, or from the USB drive to the switch. You can also start the switch using files on the USB drive. For more information about using the USB drive, see the RackSwitch G8296 Release Notes.
QSFP+ ports accept supported optical QSFP+ transceivers or direct attach cables (DACs). The supported transceivers interoperate with any 40GBASE-SR4 compliant device, and support distances up to 100 meters on OM3 fiber. Transceivers must be purchased separately. RackSwitch G8296 Installation Guide...
QSFP+ optical transceiver with MTP-to-4 LC (SFP+) fiber breakout cable. This option supports only Lenovo 10GBASE-SR SFP+ transceivers. The 40GBASE-SR4 specification (802.3ba-2010) indicates a higher optical power level than standard 10GBASE-SR. Lenovo SFP+ SR transceivers can handle the higher optical power levels. This cable must be purchased separately. •...
The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. RackSwitch G8296 Installation Guide...
Page 28
Amber Power supply failure. Power supply is operational. Green DC output power is present. DC output power is OK. Green AC power is OK. No power. Output is disabled, or input power is outside operating range. RackSwitch G8296 Installation Guide...
– “Installing the G8296 in a Standard Equipment Rack” on page 35 – “Installing the G8296 in a Lenovo System x or Power Rack” on page 37 – “Installing the G8296 in a Lenovo NeXtScale Rack” on page 41 •...
Print this page and record product information below. Keep the information in a safe place for future reference. You will need this information when you register the switch or open a service call with Lenovo. Table 9. Important product information...
Electrostatic discharge wrist strap Package Contents The basic G8296 package contains the following items: • One RackSwitch G8296 unit with front-to-rear or rear-to-front airflow • One two-post mounting kit for standard 19” equipment racks: – Two mounting brackets – Screws to attach brackets to the switch unit –...
Power cords for this product for a specific country or region are usually available only in that country or region. Power cord installation should also conform to the recommendations listed in “Cabling Guidelines” on page RackSwitch G8296 Installation Guide...
Make sure that the radius of any bend does not exceed the vendor recommended minimum bend radius. • Do not stress cables and connectors by applying additional twists, tension beyond load ratings, stapling, or applying nylon tie-wraps with a tie-wrap puller. RackSwitch G8296 Installation Guide...
4-Post Rail Kit. This kit must be purchased separately. Installation instructions begin on page • For a Lenovo NeXtScale 4-post rack, use the Lenovo Adjustable 19” 4-Post Rail Kit, installed in a recessed configuration. This kit must be purchased separately. Installation instructions begin on page...
Page 36
4. Secure the switch unit to the rack posts with M6 screws (Item 3) and either clip nuts (Item 4) or cage nuts (Item 5). Torque the screws to approximately 5.7 Nm ± 0.1 Nm (50 inch-pounds). 5. If installing the air-duct option, see the instruction on page RackSwitch G8296 Installation Guide...
68). Installing the G8296 in a Lenovo System x or Power Rack ® This section describes how to install the G8296 in a Lenovo System x or Power 4-post rack, using the Lenovo Adjustable 19” 4-Post Rail Kit. The kit must be purchased separately. It includes the following parts: Table 11.
Page 38
4. Secure the switch to the front rack posts with M6 screws (Item 3) and either clip nuts (Item 4) or cage nuts (Item 5). Torque the screws to approximately 5.7 Nm ± 0.1 Nm (50 inch-pounds). RackSwitch G8296 Installation Guide...
Page 40
“Cabling Guidelines” on page 11. Initialize the switch. See Chapter 5, “Initializing the G8296,” on page 12. If the switch is a replacement unit, set Vital Product Data (see “Configuring Vital Product Data” on page 68). RackSwitch G8296 Installation Guide...
Installing the G8296 in a Lenovo NeXtScale Rack This section describes how to install the G8296 in a Lenovo NeXtScale 4-post rack, using the Lenovo Adjustable 19” 4-Post Rail Kit. The kit must be purchased separately. It includes the following parts: Table 12.
Page 42
4. Secure the front mounting brackets to the front rack posts with M6 screws (Item 3) and either clip nuts (Item 4) or cage nuts (Item 5). Torque the screws to approximately 5.7 Nm ± 0.1 Nm (50 inch-pounds). RackSwitch G8296 Installation Guide...
Installing the Air-Duct Option The G8296 supports an optional 2U air duct to maximize air flow conditions in a Lenovo System x or Power 4-post rack. For information on removing an installed 2U air-duct option, see “Removing the Air-Duct Option” on page The following table lists the parts included with the air-duct option kit.
Page 45
1. Install the switch in a 4-post rack as described in “Installing the G8296 in a Lenovo System x or Power Rack” on page Note: If installing the 2U air-duct option to a previously mounted switch, first remove and retain the rear-bracket mounting screws and joining screws on both sides.
Page 46
± 0.1 Nm (50 inch-pounds). 4. Attach a foam baffle (Item 5) to the mounting brackets at each side of the switch with M3.5 screws (Item 6). Torque the screws to approximately 0.5 Nm (4 inch-pounds). RackSwitch G8296 Installation Guide...
Page 50
4. Connect the fiber-optic cable following the “Cabling Guidelines” on page To remove an SFP optical transceiver, disconnect the fiber-optic cable, and pull down the locking lever to release the transceiver. After you remove the transceiver, replace the safety cap. RackSwitch G8296 Installation Guide...
Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam. Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil À Laser de Classe 1 RackSwitch G8296 Installation Guide...
– “Removing the G8296 from a Standard Equipment Rack” on page 62 – “Removing the G8296 from a Lenovo System x or Power Rack” on page 63 – “Removing the G8296 from a Lenovo NeXtScale Rack” on page 65 •...
The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. RackSwitch G8296 Installation Guide...
4. Attach signal cables to other 2. Remove the signal cables from the devices. connectors. 5. Connect power cords to their 3. Remove all cables from the sources. devices. 6. Turn ON all the power sources. RackSwitch G8296 Installation Guide...
1. Select an empty fan module bay on the rear of the switch. If the target bay is covered by a blank fan filler plate, remove the blank. 2. Remove the new fan module from the antistatic shielded bag. RackSwitch G8296 Installation Guide...
4. Slide the switch unit out of the rack. 5. Loosen and remove the M4 screws attaching the mounting bracket on each side of the switch. 6. If replacing the unit with another G8296, see “Replacing the G8296” on page RackSwitch G8296 Installation Guide...
Removing the G8296 from a Lenovo System x or Power Rack This section describes how to remove the G8296 from a Lenovo System x or Power 4-post rack. To remove the G8296 from a System x or Power rack, complete the following steps: 1.
Page 64
6. Slide the G8296 unit out of the rack. 7. Loosen and remove the M4 screws that attach the front mounting brackets to each side of the switch. 8. If replacing the unit with another G8296, see “Replacing the G8296” on page RackSwitch G8296 Installation Guide...
Removing the G8296 from a Lenovo NeXtScale Rack This section describes how to remove the G8296 from a Lenovo NeXtScale 4-post rack. To remove the G8296 from a NeXtScale rack, complete the following steps: 1. Disconnect all external cables. 2. If the air-duct option has been installed, remove it as described in “Removing...
Page 66
6. Slide the G8296 unit out of the rack. 7. Loosen and remove the M4 screws that attach the front mounting brackets to each side of the switch. 8. If replacing the unit with another G8296, see “Replacing the G8296” on page RackSwitch G8296 Installation Guide...
Removing the Air-Duct Option The G8296 supports an optional 1U air duct to maximize air flow conditions in a Lenovo Power Systems Group rack. To remove an installed 1U air-duct option from a 19” rack, complete the following steps. 1. Loosen the M4 thumbscrews securing the air-duct unit to the mounting brackets.
71. At the Password prompt, the default password is admin. 2. Use the following CLI commands to enter the Executive configuration mode: RS_G8296> enable Enable privilege granted RS_G8296# configure terminal Enter configuration commands, one per line. End with Ctrl/Z. RS_G8296 (config)# RackSwitch G8296 Installation Guide...
Page 69
System Information at 0:11:46 Wed Jan 6, 2015 Time zone: America/US/Pacific Daylight Savings Time Status: Disabled Lenovo RackSwitch G8296 Switch has been up for 0 days, 0 hours, 10 minutes and 45 seconds. Last boot: 0:11:36 Wed Jan 6, 2015 (reset from console) MAC address: fc:cf:62:9d:2b:00 IP (If 1) address: 192.168.49.50...
However, if desired, you can revert the custom configuration settings to the original factory defaults. The original factory default configuration files are a permanent part of the firmware; you cannot deleted them or change their original definitions. RackSwitch G8296 Installation Guide...
Updating Firmware If firmware updates are available, you can download them from the Lenovo website. The switch might have features that are not described in the documentation that comes with the switch, and the documentation might be updated occasionally to include information about those features, or technical updates might be available to provide additional information that is not included in the switch documentation.
If you have problems accessing the switch or working with the firmware, see the Command Reference for the switch. For information about calling Lenovo for service, see Appendix A, “Getting Help and Technical Assistance”...
If you need help, service, or technical assistance or just want more information about Lenovo products, you will find a wide variety of sources available from Lenovo to assist you. This section contains information about where to go for additional information about Lenovo and Lenovo products, what to do if you experience a problem with your system, and whom to call for service, if it is necessary.
Using the Documentation Information about your Lenovo system and pre-installed software, if any, or optional device is available in the documentation that comes with the product. That documentation can include printed documents, online documents, readme files, and help files. RackSwitch G8296 Installation Guide...
Consult your local Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead.
Trademarks Lenovo, the Lenovo logo, Flex System, System x, NeXtScale System, and X-Architecture are trademarks of Lenovo in the United States, other countries, or both. Adobe and PostScript are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries.
(TBW). A device that has exceeded this limit might fail to respond to system-generated commands or might be incapable of being written to. Lenovo is not responsible for replacement of a device that has exceeded its maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the device.
If Lenovo determines that the levels of particulates or gases in your environment have caused damage to the device, Lenovo may condition provision of repair or replacement of devices or parts on implementation of appropriate remedial measures to mitigate such environmental contamination.
Further certification may be required by law prior to making any such connection. Contact a Lenovo representative or reseller for any questions. Electronic Emission Notices When you attach a monitor to the equipment, you must use the designated monitor cable and any interference suppression devices that are supplied with the monitor.
EU-Mitgliedsstaaten und hält die Grenzwerte der EN 55022 Klasse A ein. Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der Lenovo empfohlene Kabel angeschlossen werden. Lenovo übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung...
Russia Electromagnetic Interference (EMI) Class A Statement People’s Republic of China Class A Electronic Emission Statement Taiwan Class A Compliance Statement RackSwitch G8296 Installation Guide...
Note: The specific features supported on your switch, as well as some capacity and performance characteristics, depend on the specific firmware installed. For more information, see the Application Guide and Command Reference for your specific switch and its installed firmware. RackSwitch G8296 Installation Guide...