Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND
CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
! WARNING! Ensure Health & Safety, local authority, general workshop practice regulations are adhered to when using equipment.
! WARNING! Installation site must be equipped with suitable fire extinguishers (water must not be used) and escape routes.
! WARNING! Disconnect the air supply from the tank before changing accessories, servicing or performing any maintenance.
Maintain the tank in good condition (use an authorised service agent).
"
Replace or repair damaged parts. Use genuine parts only. Non-authorised parts may be dangerous and will invalidate the warranty.
"
Locate the tank in an adequate working area. Ensure the tank stands on a firm level surface. Keep area clean and tidy and free from unrelated
"
materials. Ensure the area is well ventilated and has adequate lighting.
! WARNING! Ensure correct air pressure is maintained and not exceeded. Recommended pressure 2.1 - 3.5 bar (30 - 50psi).
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use, and ensure that all connections are secure.
"
! WARNING! This tank is recommended for use only with solvents.
Use only recommended solvents as a cleaning agent, do not pour any other type of cleaning fluid into the tank.
"
Keep the tank clean. Remove and clean the suction filter regularly for best performance.
"
! WARNING! DO NOT SMOKE and keep sources of ignition, such as heaters, lamps, etc. away from the unit, together with flammable
or combustible materials, as there is an explosion risk.
! WARNING! Wear approved safety eye protection, mask and gloves. If solvent gets on skin or in eyes wash thoroughly with water
and take any other action as required by the solvent instructions.
Remove ill fitting clothing, ties, watches, rings and other loose jewellery, contain long hair, and wear appropriate protective clothing.
"
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
"
Keep non-essential persons away from the working area.
"
In case of fire in tank, do not attempt to move the unit or remove spray guns.
"
DO NOT use the tank with the lid open and DO NOT use it for spray gun testing.
#
DO NOT use the tank for any purpose other than for which it is designed.
#
DO NOT operate the tank if any parts are missing or damaged as this may cause failure or possible personal injury.
#
DO NOT over-fill the tank.
#
DO NOT direct air from the air hose at yourself or others.
#
DO NOT operate the tank when you are tired, under the influence of alcohol, drugs or intoxicating medication.
#
When cleaning is complete, ensure all controls are in the 'off' position and that the air supply is turned off.
"
! WARNING! It is operator's responsibility to ensure that there is no uncontrolled discharge of any fluids used with this unit and that
appropriate arrangements have been made for correct disposal of waste in accordance with government/local authority regulations.
2. INTRODUCTION & SPECIFICATION
The SM24/1A is a compact unit suitable for small to medium sized body shop use. The tank is robustly manufactured and delivers sufficient
solvent to clean one gun and pot in each washing cycle. The air supply is automatically cut off when the lid is opened.
SPECIFICATION: . . . . . . . . . . . . . . . . . . . . . . . . .
Operating pressure . . . . . . . . . . . . . . . .2.1-3.5 bar
Air consumption . . . . . . . . . . . . . . . . . . . . .2-4 cfm
3. ASSEMBLY
Note: Item numbers in brackets are those in the attached Parts Diagram. Instructions should be read in conjunction with this diagram.
3.1.
Attach legs to cabinet with screws (63) and nuts (65) provided and fit drain valve (66) to base of tank (2).
4.
AIR SUPPLY
NOTE: The air supply for the SM23/2 must be equipped with a regulator, filter/separator and oiler in order to ensure safe operation and to
prolong the life of the product. These items are not supplied and must be purchased separately. Consult your local Sealey dealer for a
suitable product.
For recommended hook-up, see diagram below.
4.1.
Ensure that the air valve (20) is closed before connecting the air supply.
4.2.
An air pressure of 1.5-3.5 bar (20-50psi), and an available air volume of 1cfm will be required to operate the unit.
WARNING! Ensure air supply is clean and does not exceed 5 bar(70psi). Too high an air pressure and/or unclean air will
!
shorten the product life due to excessive wear, and may be dangerous, causing possible damage and personal injury.
4.3.
Drain the air supply tank daily. Water in the air line will damage the unit.
4.4.
Clean the air supply filter weekly.
4.5.
Line pressure should be increased to compensate for unusually long air
hoses (over 8 metres). The minimum hose internal diameter should be
10mm and fittings must have the same internal dimension.
4.6.
Keep hose away from heat, oil and sharp edges. Check hoses
for wear, and make certain that all connections are secure.
4.7.
The air inlet connection is 1/4"BSP.
INSTRUCTION MANUAL FOR:
SPRAY GUN CLEANER
MODEL NO:
Cleans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 pot + 1 gun
Width x depth x height . . . . . . . . . . . . . . . . . .430 x 450 x 1300mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26kg
HOOK-UP
SM24/1A