10. Removing the Feeder Tube
Remove the purge unit. (See page 3-22.)
Remove the pressure cam home position sen-
sor. (See page 3-22 and 3-23.)
Remove 4 tubes @ from groove @ on the
pressure cam guide.
1)
2)
3)
4)
®
Figure 3-320
Remove E-ring © and draw out gear shaft ©
then remove gear @.
Remove E-ring ® and remove gear shaft ©.
Then, remofe 2 mounting screws @) in Figure 3-
320, and remove pressure cam guide @).
es
8
6
Lat
Vit LA
Figure 3-321
COPYRIGHT © 1998 CANON INC.
CHAPTER 3 MECHANICAL SYSTEM
mm
5)
Remove left and right bushing (2 hooks) @ and
remove guide roller @.
Figure 3-322
6) Remove feeder tube 42 from groove (3.
Figure 3-323
3-27