Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
1. SAFETY INSTRUCTIONS
WARNING! Ensure any Health & Safety, Government, or local authority regulations are adhered to when using this equipment.
Familiarise yourself with the application and limitations, as well as the potential hazards, of the generator.
Maintain the generator in good condition (use an authorised service agent). Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
This generator is designed and manufactured for specific applications. Do not attempt to modify the unit or use it for any application for
which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey dealer.
WARNING! DO NOT exceed the Wattage/Amperage capacity of the generator. Add rated wattage of all devices intended for connection
at anyone time. The total must not exceed rated wattage of generator (see specifications). In most cases the rated wattage of an electrical
device can be found on the nameplate. If the nameplate only gives voltage and amperage, multiply the two to give rated wattage (Volts x
Amps = Watts)
WARNING! Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient
ventilation.
WARNING! If you decide to use an Earth Leakage Circuit Breaker (also referred to as an RCD or Ground Fault Circuit Interrupter),
it is imperative that the neutral end of the power winding is connected to the frame of the generator set and that the earth lug on
the frame is connected with a low impedance connector to the local earth via an earth spike or local protective earth conductor.
This connection should only be attempted by a qualified electrician, after first having consulted your local dealer.
DANGER! This generator is designed for outdoor use only. To use the generator inside any building or enclosure, including the
generator compartment of a caravan, may result in fire or an explosion. No user performed modifications, including venting of
the exhaust and/or cooling ventilation, will eliminate the danger.
DANGER! If this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken.
Before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from
the commercial electric supply. Failure to do this may result in damage to the generator and may result in serious injury or
fatality, due to a back-feed of electrical energy.
DANGER! The generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare
wires, terminals etc. Never allow any unqualified person to operate or service the generator.
WARNING! Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat in the
vicinity while handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and handling of
fuels.
WARNING! NEVER refuel when the engine is running or when the engine is hot. Allow cool down time.
Operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt
or corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases).
Remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair. Wear appropriate protective clothing.
Keep non-essential persons away from the working area.
WARNING! Never start or stop the generator while electrical loads are connected and switched on. Start the engine, let it
stabilise, then connect the electrical load. To stop engine, disconnect the electrical load and let engine stabilise before switching
off.
WARNING! Do not use worn, bare, frayed or otherwise damaged electrical cables with the generator. To do so may result in
electric shock.
DO NOT use the generator for any purpose other than that for which it is designed.
DO NOT operate the generator if any parts are missing or damaged, as this may cause failure and/or personal injury.
DO NOT over-fill fuel tank. Always leave room for fuel to expand.
DO NOT operate in the rain.
DANGER! Do not tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase the risk
of personal injury and/or equipment damage. The generator supplies the correct rated frequency and voltage only when
running at the correct governed speed. Incorrect frequency and/or voltage can damage connected electrical loads.
Operating at excessively low speeds may result in shortened engine life. Over-speeding will invalidate the warranty.
DO NOT operate the generator when you are tired or under the influence of alcohol, drugs or intoxicating medication.
DO NOT store generator with fuel in tank where petrol vapours might reach an open flame or spark.
2. INTRODUCTION & SPECIFICATION
Heavy-duty frame design provides full protection and aids portability. Suitable for running power tools and lighting units etc. Long running, up
to 10.5 hours on a full tank. Fitted with two 230V 3-pin sockets. Powerful and reliable generator fitted with maintenance-free brushless alterna-
tor. Smooth running unit fitted with anti-vibration mountings. Low oil cut-out feature and fuel gauge.
Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.5HP
Motor Type:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Stroke
Output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V - 50Hz
Current Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1A
Cont. Power Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000W
Max Power Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2300W
INSTRUCTIONS FOR:
GENERATOR 2300W-230V
MODeL No:
Fuel Tank Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12ltr
Max Running Time: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.5hrs
Noise Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97LWA
Dry Weight:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41kg
Dimensions (L x W x H): . . . . . . . . . . . . . . .515 x 410 x 430mm
Original Language Version
G2300
G2300
Issue: 2 - 26/10/09